Real-time magnetic resonance cine imaging with sparse sampling and iterative reconstruction for ventricular measures: comparison with gold-standard segmented steady-state free precession
نویسندگان
چکیده
Background Segmented cine imaging with a steady-state free precession sequence (CINE-SSFP) is currently the gold standard technique for measuring ventricular volumes and mass. It requires multiple breath-holds to cover the entire ventricles, thus being prone to misalignment of consecutive slices, time consuming and dependent on breath-hold (BH) capability. Real-time cine avoids those limitations, however poor spatial and temporal resolution of conventional sequences have prevented its routine application. We sought to examine if a newly developed real-time sequence featuring sparse sampling and iterative reconstruction (CINE-RT), which is an investigational prototype, would yield similar results when compared with conventional CINE-SSFP in a group of healthy volunteers. Methods Stacks of short-axis cines were acquired covering both ventricles in a 1.5T system (MAGNETOM Aera, Siemens AG, Germany), using gold standard CINE-SSFP and CINE-RT. Acquisition parameters for CINE-SSFP were: voxel size 1.6x1.6x7.0mm, GRAPPA acceleration factor of 2, temporal resolution of 39 ms, retrospective gating, with an average of 8 heart beats per slice and 2 slices/BH. For CINE-RT: voxel size 1.6x1.6x7.0mm, sparse sampling net acceleration factor of 11.5, temporal resolution of 41 ms, prospective gating, real-time acquisition of 2 heart-beats/slice and all slices in one BH. Left and right ventricle contours were blindly drawn by an experienced observer at end diastole and systole to derive volumes and LV mass.
منابع مشابه
O10: Real-time magnetic resonance cine imaging with compressed sensing and iterative reconstruction for ventricular measures: comparison with gold-standard segmented steady-state free precession
O10: Real-time magnetic resonance cine imaging with compressed sensing and iterative reconstruction for ventricular measures: comparison with gold-standard segmented steady-state free precession Gabriel Camargo, Leticia R Sabioni, Thomas Doring, Ralph Strecker, Maria Eduarda Derenne, Vania M Naue, Tamara Rothstein, Michaela Schmidt, Michael O Zenge, Mariappan S Nadar, Ronaldo S Lima, Ilan Gottlieb
متن کاملFree-breathing real-time cardiac cine MR for evaluation of left-ventricular function: Comparison to standard multi-breath-hold cardiac cine MR in 50 patients
Background Electrocardiogram (ECG)-gated breath-hold cardiac cine magnetic resonance imaging (MRI) is generally accepted as the gold standard for left-ventricular (LV) volume assessment. However, it may fail in patients with arrhythmia, impaired breath-hold capacity, and poor ECG gating. Recently, sparse real-time (RT) cine using a prototype sequence with sparse sampling and iterative reconstru...
متن کاملSegmented CMR acquisition with iterative SENSE reconstruction using L1-regularization in the evaluation of right ventricular systolic function
Background Cardiac MR (CMR) has emerged as the gold standard in assessing biventricular size and systolic function with segmented balanced steady-state free-precession (bSSFP) cine acquisitions. The application of a novel prototype iterative reconstruction technique to sparsely undersampled segmented bSSFP cine acquisitions may enable higher acceleration factors while shortening image acquisiti...
متن کاملInitial experience with a cardiac multi-contrast real-time cine prototype integrating sparse sampling and iterative reconstruction
Methods All patients were submitted to a conventional cardiac magnetic resonance study (Magnetom Aera, Siemens AG Healthcare, Germany) that included shortand long-axis steady-state free-precession (SSFP) segmented cine measurements (spatial resol.: 1.5x1.5 mm; slice thickness: 7 mm; temporal resol.: 40 ms; 7 heart beats (HB)/slice), modified Look-Locker inversion recovery post-contrast T1 mappi...
متن کاملSingle breath-hold real-time MR cardiac cine for evaluation of left ventricular function
Background Magnetic Resonance (MR) cardiac cine is generally accepted as the gold standard for left ventricular (LV) volume assessment. Recently, Real-Time (RT) cine with sparse sampling technique and iterative reconstruction has been applied to accelerate cine MR. However, in prospective electrocardiogram (ECG) triggered RT cine MR, it may be difficult to capture the true end diastole phase be...
متن کامل