Comparisons of anterior segment biometry between Chinese and Caucasians using anterior segment optical coherence tomography.

نویسندگان

  • C K Leung
  • P-M Palmiero
  • R N Weinreb
  • H Li
  • Z Sbeity
  • S Dorairaj
  • D Leung
  • S Liu
  • J M Liebmann
  • N Congdon
  • D S Lam
  • R Ritch
چکیده

PURPOSE To compare anterior segment parameters between eyes of Chinese and Caucasians using anterior segment optical coherence tomography and to evaluate the association between these parameters and anterior chamber angle width between the two ethnic groups. METHODS 60 Chinese and 60 Caucasians, 30 with open angles and 30 with narrow angles (defined as Shaffer grade < or =2 in > or =3 quadrants during dark room gonioscopy) in each group, were consecutively enrolled. One eye of each subject was randomly selected for imaging in a completely darkened room. Measurements, including anterior chamber depth (ACD), scleral spur-to-scleral spur distance (anterior chamber width (ACW)), anterior chamber angle width, iris convexity and iris thickness, were compared between the groups. The associations between angle opening distance and biometric measurements were evaluated with univariate and multivariate regression analyses. RESULTS There were no differences in age, axial length, anterior chamber angle measurements, pupil diameter and iris convexity between Chinese and Caucasians in both open-angle and narrow-angle groups. However, the ACD and ACW were smaller and the iris was thicker in Chinese. In the multivariate analysis, the ACD was the most influential biometric parameter for angle opening distance in both Chinese and Caucasians. After adjusting the effects of axial length, age and sex, ACD and ACW were significantly smaller in Chinese. CONCLUSIONS Chinese eyes had smaller ACD, smaller ACW and greater iris thickness than Caucasians. ACD was the most influential parameter in determining the angle width in both ethnic groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biometry of the cornea and anterior chamber in chinese eyes: an anterior segment optical coherence tomography study.

PURPOSE. To investigate the normative data of corneal and anterior segment biometric parameters and their associations in Chinese adults, for use in preoperative assessment for corneal and anterior segment surgery. METHODS. This cross-sectional, population-based study included 750 subjects aged > or =50 years. The subjects underwent an ophthalmic examination including imaging with anterior segm...

متن کامل

Differences in baseline dark and the dark-to-light changes in anterior chamber angle parameters in whites and ethnic Chinese.

PURPOSE To assess the anterior chamber drainage angle width in the dark and the dark-to-light change (Δ) between Caucasians and Chinese aged 40 years and older. METHODS The study groups comprised four age- and sex-matched cohorts: American Caucasians, American Chinese, southern mainland Chinese, and northern mainland Chinese. Anterior segment optical coherence tomography (ASOCT) images of the...

متن کامل

Full OCT anterior segment biometry: an application in cataract surgery

In vivo three-dimensional (3-D) anterior segment biometry before and after cataract surgery was analyzed by using custom high-resolution high-speed anterior segment spectral domain Optical Coherence Tomography (OCT). The system was provided with custom algorithms for denoising, segmentation, full distortion correction (fan and optical) and merging of the anterior segment volumes (cornea, iris, ...

متن کامل

Ocular anterior segment biometry and high-order wavefront aberrations during accommodation.

PURPOSE We investigated the relationships between the ocular anterior segment biometry and the ocular high-order aberrations (HOAs) during accommodation by combined ultralong scan depth optical coherence tomography (UL-OCT) and wavefront sensor. METHODS We enrolled 35 right eyes of young healthy subjects (21 women and 14 men; age, 25.6 ± 3.1 years; spherical equivalent refractive error, -0.41...

متن کامل

Simultaneous real-time imaging of the ocular anterior segment including the ciliary muscle during accommodation

We demonstrated a novel approach of imaging the anterior segment including the ciliary muscle using combined and synchronized two spectral domain optical coherence tomography devices (SD-OCT). In one SD-OCT, a Complementary Metal-Oxide-Semiconductor Transistor (CMOS) camera and an alternating reference arm was used to image the anterior segment from the cornea to the lens. Another SD-OCT for im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 94 9  شماره 

صفحات  -

تاریخ انتشار 2010