Analytical characteristics of a continuum-source tungsten coil atomic absorption spectrometer.

نویسندگان

  • Jennifer A Rust
  • Joaquim A Nóbrega
  • Clifton P Calloway
  • Bradley T Jones
چکیده

A continuum-source tungsten coil electrothermal atomic absorption spectrometer has been assembled, evaluated, and employed in four different applications. The instrument consists of a xenon arc lamp light source, a tungsten coil atomizer, a Czerny-Turner high resolution monochromator, and a linear photodiode array detector. This instrument provides simultaneous multi-element analyses across a 4 nm spectral window with a resolution of 0.024 nm. Such a device might be useful in many different types of analyses. To demonstrate this broad appeal, four very different applications have been evaluated. First of all, the temperature of the gas phase was measured during the atomization cycle of the tungsten coil, using tin as a thermometric element. Secondly, a summation approach for two absorption lines for aluminum falling within the same spectral window (305.5-309.5 nm) was evaluated. This approach improves the sensitivity without requiring any additional preconcentration steps. The third application describes a background subtraction technique, as it is applied to the analysis of an oil emulsion sample. Finally, interference effects caused by Na on the atomization of Pb were studied. The simultaneous measurements of Pb and Na suggests that negative interference arises at least partially from competition between Pb and Na atoms for H2 in the gas phase.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fraunhofer effect atomic absorption spectrometry.

The dark lines in the solar spectrum were discovered by Wollaston and cataloged by Fraunhofer in the early days of the 19th century. Some years later, Kirchhoff explained the appearance of the dark lines: the sun was acting as a continuum light source and metals in the ground state in its atmosphere were absorbing characteristic narrow regions of the spectrum. This discovery eventually spawned ...

متن کامل

Tungsten coil devices in atomic spectrometry: absorption, fluorescence, and emission.

In this work, tungsten coil (W-Coil) devices are used as atomizers for electrothermal atomization atomic absorption spectrometry (ETAAS), electrothermal atomization laser excited atomic fluorescence spectrometry (ETA-LEAFS), and electrothermal vaporization inductively coupled plasma atomic emission spectrometry (ETV-ICP-AES). For most cases in ETAAS and ETA-LEAFS, limits of detection (LODs) usi...

متن کامل

A portable tungsten coil atomic emission spectrometer for the simultaneous determination of metals in water and soil samples.

Tungsten coil atomic emission spectrometry (WCAES) has been evaluated as a potentially portable technique for field applications. The tungsten coil (W-coil) was extracted from a commercially available slide projector bulb and used as both the atomizer and the excitation source. The coil was powered by a small solid-state power supply. A hand-held CCD spectrometer, powered from a laptop computer...

متن کامل

Evaluation of a Continuum Source Tungsten Coil Atomic Absorption Spectrometer: A Study of Zn Behavior

O desempenho de um espectrômetro de absorção atômica com filamento de tungstênio, fonte contínua de deutério, monocromador Czerny-Turner e um detector de estado sólido foi avaliado para Zn. As principais características do instrumento são a simplicidade de operação e o custo relativamente baixo. Apesar do alto limite de detecção (40 μg L, 3 desvio padrão do branco/coeficiente angular), Zn foi d...

متن کامل

Validation of an analytical method based on the high-resolution continuum source flame atomic absorption spectrometry for the fast-sequential determination of several hazardous/priority hazardous metals in soil

BACKGROUND The aim of this paper was the validation of a new analytical method based on the high-resolution continuum source flame atomic absorption spectrometry for the fast-sequential determination of several hazardous/priority hazardous metals (Ag, Cd, Co, Cr, Cu, Ni, Pb and Zn) in soil after microwave assisted digestion in aqua regia. Determinations were performed on the ContrAA 300 (Analyt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 21 8  شماره 

صفحات  -

تاریخ انتشار 2005