Evaluation of morphometric parameters calculated from breast lesion contours at ultrasonography in the distinction among BI-RADS categories*

نویسندگان

  • Julia Gregorio Calas
  • André Victor Alvarenga
  • Bianca Gutfilen
چکیده

Objective: To assess the performance of morphometric parameters calculated from breast lesion contours at ultrasonography, in the quantification of morphological features and in the distinction among BI-RADS categories 2, 3, 4 and 5. Materials and Methods: The present casuistry included 40 cases, with orthogonal imaging of patients submitted to surgery. Based on the lesions segmentation, the following five morphometric parameters were calculated: area ratio, overlap ratio, normalized residual value, circularity and depth-to-width ratio. Linear discriminant analysis was applied to select the best parameters, and ROC curve was utilized as figure of merit. Results: Overlap ratio was able to statistically distinguish breast lesions classified as BI-RADS 3 from others classified as BI-RADS 4 (α = 5%; p = 0.015). Additionally, such parameter presented the best performance in the differentiation between malignant and benign breast lesions. Conclusion: These results indicate that morphometric analysis of breast lesions at ultrasonography seems to be helpful in distinguishing patients who should undergo biopsy from those to be followed-up only with imaging methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Posterior breast cancer - mammographic and ultrasonographic features.

BACKGROUND/AIM Posterior breast cancers are located in the prepectoral region of the breast. Owing to this distinctive anatomical localization, physical examination and mammographic or ultrasonographic evaluation can be difficult. The purpose of the study was to assess possibilities of diagnostic mammography and breast ultrasonography in detection and differentiation of posterior breast cancers...

متن کامل

Relationship between BI-RADS 4 Ultrasound Index and Pathological Findings and Clinical Outcomes in Breast Lesions

Introduction: breast cancer is listed as the most common type of cancer in women and many patients suffer from this disease worldwide. However, the timely diagnosis of the condition can lower the rate of mortality and morbidity. Breast imaging-reporting and data system (BI-RADS) is a noninvasive scoring system. The aim of our study was to assess the BI-RADS for patients and evaluate the corresp...

متن کامل

Accuracy of sonographic findings in breast cancer: correlation between BI-RADS® categories and histological findings* Acurácia dos achados ultrassonográficos do câncer de mama: correlação da classificação BI-RADS® e achados histológicos

OBJECTIVE: The main purpose of the present study is to evaluate the accuracy of ultrasonography (BI-RADS) in the diagnosis of breast cancer whereas the additional specific objectives are to describe the frequency of different sonographic findings and evaluating interobserver agreement. MATERIALS AND METHODS: Images of 110 patients who had been referred for biopsy with previous diagnosis of brea...

متن کامل

Diagnostic value of breast ultrasound in mammography BI-RADS 0 and clinically indeterminate or suspicious of malignancy breast lesions.

BACKGROUND/AIM Not only that ultrasound makes the difference between cystic and solid changes in breast tissue, as it was the case at the beginning of its use, but it also makes the differential diagnosis in terms of benign-malignant. The aim of this study was to assess the role of sonography in the diagnosis of palpable breast masses according to the American College of Radiology Ultrasonograp...

متن کامل

The Automated Breast Volume Scanner (ABVS): initial experiences in lesion detection compared with conventional handheld B-mode ultrasound: a pilot study of 50 cases

The idea of an automated whole breast ultrasound was developed three decades ago. We present our initial experiences with the latest technical advance in this technique, the automated breast volume scanner (ABVS) ACUSON S2000(™). Volume data sets were collected from 50 patients and a database containing 23 women with no detectable lesions in conventional ultrasound (BI-RADS(®)-US 1), 13 women w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011