Reproducibility analysis on shear wave elastography (SWE)-based quantitative assessment for skin elasticity

نویسندگان

  • Yang Sun
  • Chuan Ma
  • XiaoLong Liang
  • Run Wang
  • Ying Fu
  • ShuMin Wang
  • LiGang Cui
  • ChunLei Zhang
چکیده

Shear Wave Elastography (SWE) is an objective and non-invasive method widely used to quantify the tissue solidity. However, there are concerns about the accuracy of the skin SWE results due to the low signal-to-noise ratio (SNR) caused by subcutaneous fat, muscle and bone. This article analyzed the reproducibility of the result for skin SWE and therefore evaluated the availability of SME for skin elasticity involved diseases. Thirty volunteers (mean age: 37 ± 12 years) were selected. SWE were taken on the skin of abdomen and the middle tibia in order to assess the impact of fat, muscle and bone on SWE results. Skin in the area of anterior and lateral tibia marked with seven parallel lines, and each line indicated an identical thickness of the subcutaneous fat from 1-7 mm. Intra-class correlation coefficients (ICC) were used to evaluate the intra-observer and inter-observer reproducibility. The solidity of abdominal skin showed soft and small individual differences (12.4 ± 2.7 kPa), whereas high shear moduli (25-48 kPa) were observed in the skin above tibia and tibialis anterior muscle. When the subcutaneous fat was thicker than 3 mm (≥3), we obtained excellent intra-observer reproducibility (ICC range 0.78-0.98) and inter-observer reproducibility (ICC range 0.75-0.98). The thickness of subcutaneous fat could affect the reproducibility of skin SWE. The further study on skin SWE standardization should be taken.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the diagnostic function of shear wave elastography in the differentiation of malignant and benign breast masses and its relationship with histological factors

Background: Shear wave elastography (SWE) estimates the stiffness of a mass based on the velocity of shear wave propagation by sound waves. Due to higher cell density and angiogenesis, malignant masses have higher stiffness than benign ones. Methods: The present study was a prospective study and was performed on patients who were referred to Ahvaz Golestan Hospital with breast mass during Marc...

متن کامل

2-dimensional shear wave elastography: Interobserver agreement and factors related to interobserver discrepancy

PURPOSE To evaluate the interobserver reproducibility of two-dimensional shear wave elastography (2D-SWE) in measuring liver stiffness (LS) and to investigate factors related to liver 2D-SWE. MATERIALS AND METHODS A prospective study was conducted between August 2011 and August 2012 in rheumatoid arthritis patients who had been treated with methotrexate. Interobserver reproducibility of 2D-SW...

متن کامل

Shear wave elastography imaging of carotid plaques: feasible, reproducible and of clinical potential

BACKGROUND Shear Wave Elastography (SWE) imaging is a novel ultrasound technique for quantifying tissue elasticity. Studies have demonstrated that SWE is able to differentiate between diseased and normal tissue in a wide range clinical applications. However its applicability to atherosclerotic carotid disease has not been established. The aim of this study was to assess the feasibility and pote...

متن کامل

Quantitative and noninvasive assessment of chronic liver diseases using two-dimensional shear wave elastography

Two-dimensional shear wave elastography (2D-SWE) is a rapid, simple and novel noninvasive method that has been proposed for assessing hepatic fibrosis in patients with chronic liver diseases (CLDs) based on measurements of liver stiffness. 2D-SWE can be performed easily at the bedside or in an outpatient clinic and yields immediate results with good reproducibility. Furthermore, 2D-SWE was an e...

متن کامل

Can continuous scans in orthogonal planes improve diagnostic performance of shear wave elastography for breast lesions?

BACKGROUND Static shear wave elastography (SWE) is used to detect breast lesions, but slice and plane selections result in discrepancies. OBJECTIVE To evaluate the intraobserver reproducibility of continuous SWE, and whether quantitative elasticities in orthogonal planes perform better in the differential diagnosis of breast lesions. METHOD One hundred and twenty-two breast lesions schedule...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2017