Evaluation of deformable registration of patient lung 4DCT with subanatomical region segmentations.

نویسندگان

  • Ziji Wu
  • Eike Rietzel
  • Vlad Boldea
  • David Sarrut
  • Gregory C Sharp
چکیده

Deformable registration is needed for a variety of tasks in establishing the voxel correspondence between respiratory phases. Most registration algorithms assume or imply that the deformation field is smooth and continuous everywhere. However, the lungs are contained within closed invaginated sacs called pleurae and are allowed to slide almost independently along the chest wall. This sliding motion is characterized by a discontinuous vector field, which cannot be generated using standard deformable registration methods. The authors have developed a registration method that can create discontinuous vector fields at the boundaries of anatomical subregions. Registration is performed independently on each subregion, with a boundary-matching penalty used to prevent gaps. This method was implemented and tested using both the B-spline and Demons registration algorithms in the Insight Segmentation and Registration Toolkit. The authors have validated this method on four patient 4DCT data sets for registration of the end-inhalation and end-exhalation volumes. Multiple experts identified homologous points in the lungs and along the ribs in the two respiratory phases. Statistical analyses of the mismatch of the homologous points before and after registration demonstrated improved overall accuracy for both algorithms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images

Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DI...

متن کامل

Deformable registration of 4DCT data for ion beam therapy of moving tumors*

For radiotherapy with ion beams precise information of the patient's internal anatomy is required. For moving organs such as lung or liver, time-resolved (4D) computed tomography (CT) can be applied to extract anatomical changes due to respiration of a patient. A 4DCT data set consists of several 3-dimensional (3D) CT volumes (typically 10), and each volume corresponds to the anatomical 3D imag...

متن کامل

Interactive Deformable Registration Visualization and Analysis of 4D Computed Tomography

This paper presents a new interactive method for analyzing 4D Computed Tomography (4DCT) datasets for patient care and research. Deformable registration algorithms are commonly used to observe the trajectories of individual voxels from one respiratory phase to another. Our system provides users with the capability to visualize these trajectories while simultaneously rendering anatomical volumes...

متن کامل

Calculation of Inter- and Intra-Fraction Motion Errors at External Radiotherapy Using a Markerless Strategy Based on Image Registration Combined with Correlation Model

Introduction: A new method based on image registration technique and an intelligent correlation model to calculate. The present study aimed to propose inter- and intra-fraction motion errors in order to address the limitations of conventional Patient positioning methods. Material and Methods: The configuration of the markerless method wa...

متن کامل

Validating Dose Uncertainty Estimates Produced by AUTODIRECT: An Automated Program to Evaluate Deformable Image Registration Accuracy

Deformable image registration is a powerful tool for mapping information, such as radiation therapy dose calculations, from one computed tomography image to another. However, deformable image registration is susceptible to mapping errors. Recently, an automated deformable image registration evaluation of confidence tool was proposed to predict voxel-specific deformable image registration dose m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 2008