An end-tidal sampler for use with slow response analysers during anaesthesia.
نویسندگان
چکیده
An end-tidal sampler is described which can be used during anaesthesia with spontaneous respiration at rates of at least 60 b.p.m. It can be used with slow response analysers such as refractometers and fuel cells to indicate end-tidal concentrations. It can also be used to extend the scope of those breath-to-breath analysers which have a response time which is too slow for the respiratory rates which may occur during anaesthesia with spontaneous breathing. Using the device, mean PCO2 of the samples was 0.13 kPa less than the corresponding values for the end-expiratory PCO2 measured by conventional breath-by-breath analysis. Full response was achieved in 12 breaths.
منابع مشابه
Estimation of arterial PCO2 during high frequency jet ventilation. Studies in the dog.
The arterial to end-tidal PCO2 difference (PaCO2-PE'CO2) was measured in five anaesthetized dogs during controlled ventilation at 0.25 Hz (15 b.p.m.) and during high frequency jet ventilation at 1, 3 and 5 Hz. Because of the slow response of the infra-red carbon dioxide analyser, satisfactory recordings of end-tidal carbon dioxide could not be obtained at frequencies greater than 1 Hz. The inte...
متن کاملModel-based automatic feedback control versus human control of end-tidal isoflurane concentration using low-flow anaesthesia.
We studied the clinical use of an automatic feedback control system to adjust the end-tidal anaesthetic concentration with a low-flow method. The end-tidal controller uses two input signals (the end-tidal and inspiratory concentrations) to control the isoflurane concentration in the fresh gas flow, using a model-based algorithm. We studied 22 ASA I-III patients during elective surgery lasting m...
متن کاملComparison of end-tidal and arterial carbon dioxide measurements during anaesthesia with the laryngeal mask airway.
We have confirmed the value of measurement of end-tidal carbon dioxide concentration as an indicator of arterial carbon dioxide tension during the use of the laryngeal mask airway in healthy patients breathing spontaneously. The mean difference between arterial and end-tidal carbon dioxide tension was 0.52 kPa (range 0-1.5 kPa), which is similar to the difference which has been reported when a ...
متن کاملThe effect of hypernatraemia on ketamine anaesthesia in male rats
We studied the effects of a single ketamine injection in an experimental model of chronic hypernatraemia in rats. Three groups, each of 20 male Wistar rats were chosen for the experiment; the control group was given water and the test groups were given 1% (group 1) and 2% (group 2) NaCl solutions for two weeks. All groups were fed with the same diet, containing about 0.5% salt. Other living con...
متن کاملMAC-awake of isoflurane, enflurane and halothane evaluated by slow and fast alveolar washout.
End-tidal anaesthetic concentrations at first eye opening in response to a verbal command during recovery from anaesthesia (MAC-awake), were measured for isoflurane (n = 16), enflurane (n = 16) and halothane (n = 14). MAC-awake was measured during either slow or fast alveolar washout. Slow washout was obtained by decreasing anaesthetic concentrations in predetermined steps of 15 min, assuming e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 58 10 شماره
صفحات -
تاریخ انتشار 1986