Calcium Silicate Bricks – Ultrasonic Pulse Method: Effects of Natural Frequency of Transducers on Measurement Results
نویسنده
چکیده
Modulus of elasticity is one of the important parameters of construction materials, which considerably influence their deformation properties and which can also be determined by means of non-destructive test methods like ultrasonic pulse method. However, measurement results of ultrasonic pulse methods are influenced by various factors, one of which is the natural frequency of the transducers. The paper states knowledge about influence of natural frequency of the transducers (54; 82 and 150kHz) on ultrasonic pulse velocity and dynamic modulus of elasticity (Young's Dynamic modulus of elasticity). Differences between ultrasonic pulse velocity and dynamic modulus of elasticity were found with the same smallest dimension of test specimen in the direction of sounding and density their value decreases as the natural frequency of transducers grew. Keywords—Calcium silicate brick, ultrasonic pulse method, ultrasonic pulse velocity, dynamic modulus of elasticity.
منابع مشابه
Determine the Compressive Strength of Calcium Silicate Bricks by Combined Nondestructive Method
The paper deals with the application of combined nondestructive method for assessment of compressive strength of calcium silicate bricks. In this case, it is a combination of the rebound hammer method and ultrasonic pulse method. Calibration relationships for determining compressive strength of calcium silicate bricks obtained from nondestructive parameter testing for the combined method as wel...
متن کاملUse of Non-Destructive Ultrasonic Pulse Testing Methods in Evaluation of Brick Parameters
Currently, building industry uses non-destructive testing methods primarily for evaluation of concrete quality. Efficiency of ultrasonic pulse method (UPM) was proved in order to determine compressive strength of solid bricks (concrete, calcium silicate and burnt ones). Parameters obtained from UPM testing (such as ultrasonic pulse velocity, dynamic modulus of elasticity) are affected by shape/...
متن کاملPiezoceramic Element Design and Fabrication for Ultrasonic Transducer of Gas Meter
Ultrasonic transducers play a significant role in generating and receiving the acoustic waves in ultrasonic flowmeters. Depending on the required accuracy, the ultrasonic transducers can be installed either in one pair or more in an ultrasonic flowmeter. The main part of an ultrasonic transducer is its piezoceramic element. In this work, four piezoceramic elements with different diameter to thi...
متن کاملHIGH TEMPERATURE ELASTIC PROPERTIES OF REFRACTORY MATERIALS
Abstract: A pulse-echo technique, based on ultrasonic "long-bar" mode (LBM) velocity measurements, working up to 1700°C is described. Magnetostrictive transducers and ultrasonic lines used in a 40-85 kHz frequency range are detailed. The conditions of choice of fundamental parameters (frequency, line geometry, sample size) are discussed in relation with the nature and the microstructure of ...
متن کاملImpact Analysis of Variation in Geometrical Features on Intrinsic Characteristics of Capacitive Micro-machined Ultrasonic Transducers
Capacitive Micro-machined Ultrasonic Transducers (CMUTs) are the ultrasonic devices which produce better features in contrast to piezoelectric transducers. The intrinsic parameter of CMUT varies with the variation in geometrical dimension of the device. The cavity height and the radius of the CMUT with circular membrane is varied in the lumped parallel plate model for its impact on the paramete...