X-ray microtomography application in pore space reservoir rock.
نویسندگان
چکیده
Characterization of porosity in carbonate rocks is important in the oil and gas industry since a major hydrocarbons field is formed by this lithology and they have a complex media porous. In this context, this research presents a study of the pore space in limestones rocks by x-ray microtomography. Total porosity, type of porosity and pore size distribution were evaluated from 3D high resolution images. Results show that carbonate rocks has a complex pore space system with different pores types at the same facies.
منابع مشابه
Microtomography and Pore-Scale Modeling of Two-Phase Fluid Distribution
Synchrotron-based X-ray microtomography (micro CT) at the Advanced Light Source (ALS) line 8.3.2 at the Lawrence Berkeley National Laboratory produces threedimensional micron-scale-resolution digital images of the pore space of the reservoir rock along with the spacial distribution of the fluids. Pore-scale visualization of carbon dioxide flooding experiments performed at a reservoir pressure d...
متن کاملReservoir Condition Pore-scale Imaging of Multiple Fluid Phases Using X-ray Microtomography
X-ray microtomography was used to image, at a resolution of 6.6 µm, the pore-scale arrangement of residual carbon dioxide ganglia in the pore-space of a carbonate rock at pressures and temperatures representative of typical formations used for CO2 storage. Chemical equilibrium between the CO2, brine and rock phases was maintained using a high pressure high temperature reactor, replicating condi...
متن کاملPore-scale imaging of trapped supercritical carbon dioxide in sandstones and carbonates
Geological carbon dioxide storage must be designed such that the CO2 cannot escape from the rock formation into which it is injected, and often simple stratigraphic trapping is insufficient. CO2 can be trapped in the pore space as droplets surrounded by water through capillary trapping. X-ray microtomography was used to image, at a resolution of 6.6 m, the pore-scale arrangement of these drople...
متن کاملPore-by-pore capillary pressure measurements using X-ray microtomography at reservoir conditions: Curvature, snap-off, and remobilization of residual CO2
X-ray microtomography was used to image the shape and size of residual ganglia of supercritical CO2 at resolutions of 3.5 and 2 lm and at representative subsurface conditions of temperature and pressure. The capillary pressure for each ganglion was found by measuring the curvature of the CO2-brine interface, while the pore structure was parameterized using distance maps of the pore space. The f...
متن کاملPore-scale Heterogeneity Assessed by the Lattice-boltzmann Method
A digital imaging technique is used to characterize pore-scale structures and to predict fluid flow at the scale. Heterogeneity at the pore-scale can be assessed by the micro-Computed Tomography (micro-CT), which provides complicated boundary conditions of porous media, and it can also be identified by the numerical flow simulation using the lattice-Boltzmann method (LBM) on the digital image. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
دوره 70 7 شماره
صفحات -
تاریخ انتشار 2012