Algorithm for image reconstruction in multi-slice helical CT.

نویسندگان

  • K Taguchi
  • H Aradate
چکیده

Efforts are being made to develop a new type of CT system that can scan volumes over a large range within a short time with thin slice images. One of the most promising approaches is the combination of helical scanning with multi-slice CT, which involves several detector arrays stacked in the z direction. However, the algorithm for image reconstruction remains one of the biggest problems in multi-slice CT. Two helical interpolation methods for single-slice CT, 360LI and 180LI, were used a starting points and extended to multi-slice CT. The extended methods, however, had a serious image quality problem due to the following three reasons: (1) excessively close slice positions of the complementary and direct data, resulting in a larger sampling interval; (2) the existence of several discontinuous changeovers in pairs of data samples for interpolation; and (3) the existence of cone angles. Therefore we have proposed a new algorithm to overcome the problem. It consists of the following three parts: (1) optimized sampling scan; (2) filter interpolation; and (3) fan-beam reconstruction. Optimized sampling scan refers to a special type of multi-slice helical scan developed to shift the slice position of complementary data and to acquire data with a much smaller sampling interval in the z direction. Filter interpolation refers to a filtering process performed in the z direction using several data. The normal fan-beam reconstruction technique is used. The section sensitivity profile (SSP) and image quality for four-array multi-slice CT were investigated by computer simulations. Combinations of three types of optimized sampling scan and various filter widths were used. The algorithm enables us to achieve acceptable image quality and spatial resolution at a scanning speed that is about three times faster than that for single-slice CT. The noise characteristics show that the proposed algorithm efficiently utilizes the data collected with optimized sampling scan. The new algorithm allows suitable combinations of scan and filter parameters to be selected to meet the purpose of each examination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-slice helical CT: scan and reconstruction.

The multi-slice CT scanner refers to a special CT system equipped with a multiple-row detector array to simultaneously collect data at different slice locations. The multi-slice CT scanner has the capability of rapidly scanning large longitudinal (z) volume with high z-axis resolution. It also presents new challenges and new characteristics. In this paper, we study the scan and reconstruction p...

متن کامل

A Model-Based 3D Multi-slice Helical CT Reconstruction Algorithm for Transportation Security Application

Computed tomography (CT) is widely used in transportation security applications [1], [2]. Among various CT scanner geometries, multi-slice helical CT has come into wide use due to its fast acquisition and large scan coverage. In fact, many airports have installed multi-slice helical CT systems as a central component of baggage screening. However, the more complex geometry of multi-slice helical...

متن کامل

Guest Editorial - Multirow Detector and Cone-Beam Spiral/Helical CT

S PIRAL/HELICAL multirow detector computed tomog-raphy (MDCT), also referred to as multislice spiral CT (MSCT), has attracted a major interest since its recent introduction [18], [33]. Compared with single-row-detector systems, MDCT scanners allow faster data collection and thinner slices that support more demanding clinical applications and present new research opportunities. This special issu...

متن کامل

A Hybrid Method for Segmentation and Visualization of Teeth in Multi-Slice CT scan Images

Introduction: Various computer assisted medical procedures such as dental implant, orthodontic planning, face, jaw and cosmetic surgeries require automatic quantification and volumetric visualization of teeth. In this regard, segmentation is a major step. Material and Methods: In this paper, inspired by our previous experiences and considering the anatomical knowledge of teeth and jaws, we prop...

متن کامل

Exact and approximate algorithms for helical cone-beam CT.

This paper concerns image reconstruction for helical x-ray transmission tomography (CT) with multi-row detectors. We introduce two approximate cone-beam (CB) filtered-backprojection (FBP) algorithms of the Feldkamp type, obtained by extending to three dimensions (3D) two recently proposed exact FBP algorithms for 2D fan-beam reconstruction. The new algorithms are similar to the standard Feldkam...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 25 4  شماره 

صفحات  -

تاریخ انتشار 1998