A disposable blood cyanide sensor.

نویسندگان

  • Yong Tian
  • Purnendu K Dasgupta
  • Sari B Mahon
  • Jian Ma
  • Matthew Brenner
  • Jian-Hua Wang
  • Gerry R Boss
چکیده

Deaths due to smoke inhalation in fires are often due to poisoning by HCN. Rapid administration of antidotes can result in complete resuscitation of the patient but judicious dosing requires the knowledge of the level of cyanide exposure. Rapid sensitive means for blood cyanide quantitation are needed. Hydroxocyanocobinamide (OH(CN)Cbi) reacts with cyanide rapidly; this is accompanied by a large spectral change. The disposable device consists of a pair of nested petri dish bottoms and a single top that fits the outer bottom dish. The top cover has a diametrically strung porous polypropylene membrane tube filled with aqueous OH(CN)Cbi. One end of the tube terminates in an amber (583nm) light emitting diode; the other end in a photodiode via an acrylic optical fiber. An aliquot of the blood sample is put in the inner dish, the assembly covered and acid is added through a port in the cover. Evolved HCN diffuses into the OH(CN)Cbi solution and the absorbance in the long path porous membrane tube cell is measured within 160 s. The LOD was 0.047, 1.0, 0.15, 5.0 and 2.2 μM, respectively, for water (1 mL), bovine blood (100 μL, 1 mL), and rabbit blood (20 μL, 50 μL). RSDs were<10% in all cases and the linear range extended from 0.5 to 200 μM. The method was validated against a microdiffusion approach and applied to the measurement of cyanide in rabbit and human blood. The disposable device permits field measurement of blood cyanide in <4 min.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Disposable single-use electrochemical sensor: A novel hollow fiber based tool for environmental monitoring of cadmium

The objective of this study is to design a simple, fast, sensitive and single-use electrode with the simultaneous capability of preconcentration and measuring, for application in a three-electrode voltammetry system to identify and measure the heavy metal cadmium. The design process of this sensor consists of several stages. The polyurethane foam and multi walled carbon nanotubes nanoparticles ...

متن کامل

Electrochemical Determination of Neonicotinoid Insecticide Clothianidin by Nanomaterial based Disposable Electrode

Disposable, selective and low-cost carbon nanotube modified electrodes were fabricated for the electrochemical detection of neonicotinoid insecticide, Clothianidin (CLT). Almost 2 folds’ increase at Clothianidin reduction signal was obtained by using single-walled carbon nanotube modified electrodes (SWCNT-PGE) compared to unmodified electrodes. These nanomaterials modified electrodes developed...

متن کامل

Development of a Fluorescence-Based Sensor for Rapid Diagnosis of Cyanide Exposure

Although commonly known as a highly toxic chemical, cyanide is also an essential reagent for many industrial processes in areas such as mining, electroplating, and synthetic fiber production. The "heavy" use of cyanide in these industries, along with its necessary transportation, increases the possibility of human exposure. Because the onset of cyanide toxicity is fast, a rapid, sensitive, and ...

متن کامل

Direct determination of free cyanide in drinking water by ion chromatography with pulsed amperometric detection.

Cyanide is a regulated contaminant in drinking water in the United States. This paper describes an ion chromatography method with pulsed amperometric detection (PAD) that directly determines free cyanide in drinking water. Samples are treated with sodium hydroxide to stabilize cyanide and with a cation-exchange cartridge to remove transition metals. Cyanide is separated by anion-exchange chroma...

متن کامل

Toxicological Investigation of Acute Cyanide Poisoning of a 29-year-old Man: A Case Report

Background: Cyanide poisoning is frequently lethal, Because of the early onset of severe symptoms and difficulty in the diagnosis. Case: The case was a 29-year-old boy who collapsed suddenly after taking a bottle of beer in a bar. Samples, such as peripheral blood, stomach contents, bile fluid, urine and mouth swabs, were prepared using standard autopsy procedure and were subjected to analysis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytica chimica acta

دوره 768  شماره 

صفحات  -

تاریخ انتشار 2013