Frequency and phase drift correction of magnetic resonance spectroscopy data by spectral registration in the time domain.

نویسندگان

  • Jamie Near
  • Richard Edden
  • C John Evans
  • Raphaël Paquin
  • Ashley Harris
  • Peter Jezzard
چکیده

PURPOSE Frequency and phase drifts are a common problem in the acquisition of in vivo magnetic resonance spectroscopy (MRS) data. If not accounted for, frequency and phase drifts will result in artifactual broadening of spectral peaks, distortion of spectral lineshapes, and a reduction in signal-to-noise ratio (SNR). We present herein a new method for estimating and correcting frequency and phase drifts in in vivo MRS data. METHODS We used a simple method of fitting each spectral average to a reference scan (often the first average in the series) in the time domain through adjustment of frequency and phase terms. Due to the similarity with image registration, this method is referred to as "spectral registration." Using simulated data with known frequency and phase drifts, the performance of spectral registration was compared with two existing methods at various SNR levels. RESULTS Spectral registration performed well in comparison with the other methods tested in terms of both frequency and phase drift estimation. CONCLUSIONS Spectral registration provides an effective method for frequency and phase drift correction. It does not involve the collection of navigator echoes, and does not rely on any specific resonances, such as residual water or creatine, making it highly versatile.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frequency-selective Quantiication of Biomedical Magnetic Resonance Spectroscopy Data 1 Frequency-selective Quantiication of Biomedical Magnetic Resonance Spectroscopy Data

In this paper we focus on model tting techniques in both the time and frequency domain for analysis of biomedical magnetic resonance spectroscopy (MRS) signals. We examine the possibility to obtain accurate estimates of the parameters of selected peaks in the presence of unknown or uninteresting spectral features. We denote this by frequency-selective parameter estimation. A number of existing ...

متن کامل

Correction of frequency drifts induced by gradient heating in 1H spectra using interleaved reference spectroscopy.

PURPOSE To evaluate the impact of heating-induced frequency drifts on single-voxel spectroscopy and to demonstrate correction strategies based on the interleaved reference scan technique. MATERIALS AND METHODS Frequency drifts induced by gradient heating are assessed for two clinical 3 Tesla (T) whole body MR systems. The interleaved reference scan (IRS) method is used for correcting these fr...

متن کامل

Detection of Glioblastoma Multiforme Tumor in Magnetic Resonance Spectroscopy Based on Support Vector Machine

Introduction: The brain tumor is an abnormal growth of tissue in the brain, which is one of the most important challenges in neurology. Brain tumors have different types. Some brain tumors are benign and some brain tumors are cancerous and malignant. Glioblastoma Multiforme (GBM) is the most common and deadliest malignant brain tumor in adults. The average survival rate for peo...

متن کامل

Frequency domain analysis of transient flow in pipelines; application of the genetic programming to reduce the linearization errors

The transient flow analyzing by the frequency domain method (FDM) is computationally much faster than the method of characteristic (MOC) in the time domain. FDM needs no discretization in time and space, but requires the linearization of governing equations and boundary conditions. Hence, the FDM is only valid for small perturbations in which the system’s hydraulics is almost linear. In this st...

متن کامل

New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 73 1  شماره 

صفحات  -

تاریخ انتشار 2015