Posterior Tibial Polyethylene Fracture in Cruciate-Retaining Total Knee Arthroplasty
نویسندگان
چکیده
Introduction One of the common prostheses for primary total knee arthroplasty (TKA) is a cruciate-retaining (CR) design. The tibial polyethylene inserts commonly used in TKA are made of ultra-high molecular weight polyethylene (UHMWPE). The CR TKA design retains the posterior cruciate ligament (PCL), which is believed to provide increased stability, promote femoral roll back, improve proprioception, and enhance stair-climbing ability. Delamination, adhesive wear, and abrasive wear of the polyethylene component are common mechanisms of failure, but fracture of the component at the posterior side in a CR TKA is rare. The cause of this type of failure is often multifactorial. This case report presents a case of posteromedial polyethylene fracture in a CR TKA.
منابع مشابه
Polyethylene Bearing Stress Fractures after Mobile-bearing Cruciate-retaining Total Knee Arthroplasty: Case Reports
Some reported bearing fractures are due to entrapment of the bearing between the femoral component and posterior edge of the tibial base plate in unstable meniscal –bearing design TKA. However, so far no cases of bearing fracture has been reported for the rotating platform or anteroposterior gliding designs of mobile bearing TKA. The authors describe two cases of polyethylene stress fracture af...
متن کاملPosterior cruciate-retaining, rotating-platform total knee arthroplasty: minimum 4-year follow-up study.
Rotating-platform, mobile-bearing total knee arthroplasty was initially developed using a posterior cruciate-sacrificing technique and design. Posterior cruciate-substituting and -retaining, rotating-platform total knee arthroplasty designs were developed later. The purpose of this study was to evaluate a minimum 4-year follow-up of total knee arthroplasty performed with a posterior cruciate-re...
متن کاملEffects of Tibial Insert Slope on Polyethylene Wear and Stress
INTRODUCTION: Both posterior stabilized (PS) and cruciate retaining (CR) total knee replacement systems have demonstrated high rates of survivorship, high clinical knee scores and high patient satisfaction scores for decades. However, CR total knees sometimes exhibit more varied kinematics and a smaller range of motion than similar PS knees. Many factors can cause this, but one important factor...
متن کاملFracture of Two Moderately Cross-Linked Polyethylene Tibial Inserts in a TKR Patient
Highly cross-linked polyethylene has become the gold standard in total hip replacement for its wear resistance. Moderately crosslinked polyethylene is now available for total knee replacement (TKR), although concerns about reduced mechanical strength have prevented widespread adoption. The purpose of this report is to describe an unusual case where a patient underwent cruciate retaining TKR usi...
متن کاملPosterior cruciate ligament balancing in total knee replacement: the quantitative relationship between tightness of the flexion gap and tibial translation.
We have examined the relationship between the size of the flexion gap and the anterior translation of the tibia in flexion during implantation of a posterior cruciate ligament (PCL)-retaining BalanSys total knee replacement (TKR). In 91 knees, the flexion gap and anterior tibial translation were measured intra-operatively using a custom-made, flexible tensor-spacer device. The results showed th...
متن کامل