Technical and clinical assessment of oxygen concentrators.

نویسندگان

  • G A Gould
  • W Scott
  • M D Hayhurst
  • D C Flenley
چکیده

One membrane oxygen enricher (Oxygen Enrichment Company OE-4E) and four molecular sieve (MS) concentrators (Mountain Medical Econo2, De Vilbiss MINI DeVO2, Cryogenic Roomate III, and Mountain Medical Mini O2) have been studied to assess technical and clinical performance. During four weeks of continuous operation at a flow rate of 2 l min-1 (6 l min-1 for OE-4E) consistent oxygen levels were delivered by all machines (mean greater than 93% for MS concentrators, 36.5% for OE-4E). At flow rates of up to 21 mm-1 all four MS machines delivered oxygen concentrations greater than 92%, but at 3 l min-1 (Econo2 89.6%, MINI DeVO2 93.9%, Roomate III 92.0%, Mini O2 85.0%) and at 4 l min-1 (Econo2 78.0%, Mini DeVO2 84.7%, Roomate III 83.3%, Mini O2 69.1%) the two newer machines gave higher oxygen concentrations. In 20 hypoxic patients the mean oxygen saturation levels achieved when they were breathing oxygen from the MS concentrators at a flow rate of 2 l min-1 were similar (Econo2 92.6%, MINI DeVO2 92.5%, Roomate II 92.6%), but the level achieved when they were breathing from the OE-4E, at the equivalent flow rate of 6 l min-1, was lower (91.0%, p less than 0.005). The performance of concentrators in service (Econo2, MINI DeVO2, Mini O2) was satisfactory when judged by patients' oxygen saturation levels and delivered oxygen concentrations. The OE-4E may be indicated for a small number of patients who require oxygen with high humidification. The four MS concentrators studied are all suitable for domiciliary use, but the MINI DeVO2 and Roomate III have advantages in terms of better performance at high flow rates and reduced size and weight.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Beyond good intentions: lessons on equipment donation from an African hospital.

OBJECTIVE In 2000, a referral hospital in the Gambia accepted a donation of oxygen concentrators to help maintain oxygen supplies. The concentrators broke down and were put into storage. A case study was done to find the reasons for the problem and to draw lessons to help improve both oxygen supplies and the success of future equipment donations. METHODS A technical assessment of the concentr...

متن کامل

Insufficient oxygen concentration obtained at domiciliary controls of eighteen concentrators.

The oxygen concentration (O2%) produced by 12 type A concentrators, with a working time of 28-18,099 h, and 6 type B concentrators, with a working time of 0-3,033 h, was measured over a 12 month period in the user's home, at a flow rate of 2 l.min-1. One hundred and two measurements of O2% (mean 82.9), made at least once monthly by a visiting nurse, showed that type A concentrators were usually...

متن کامل

Prescription of oxygen concentrators: adherence to published guidelines.

The indications for the prescription of oxygen concentrators have been assessed in 82 patients against the Department of Health guidelines, except that only one set of blood gas and spirometry measurements was required if the patient's condition was stable. Of the 49 patients recommended for this treatment by a chest physician, 41 (82%) fulfilled the requirements, compared with only 11 of 33 pa...

متن کامل

Assessment of oxidative stress parameters of brain-derived neurotrophic factor heterozygous mice in acute stress model

Objective(s): Exposing to stress may be associated with increased production of reactive oxygen species (ROS). Therefore, high level of oxidative stress may eventually give rise to accumulation of oxidative damage and development of numerous neurodegenerative diseases. It has been presented that brain-derived neurotrophic factor (BDNF) supports neurons against various neurodegenerative conditio...

متن کامل

Compliance with long-term oxygen therapy by concentrator.

Controlled oxygen therapy has been developed to treat chronic respiratory failure in patients with hypoxic obstructive airways disease (COAD). In two studies published in the early 1980's long term oxygen therapy (LTOT) improved survival and reduced clinical deterioration over a three year period in such patients (1, 2]. The reduction in mortality was proportionate to the number of hours per da...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 40 11  شماره 

صفحات  -

تاریخ انتشار 1985