Marginal fit of indirect composite inlays using a new system for manual fabrication.

نویسندگان

  • P Pott
  • A Rzasa
  • M Stiesch
  • M Eisenburger
چکیده

AIM This in vitro study compares a new system for manual chair side fabrication of indirect composite restorations, which uses silicone models after alginate impressions, to CAD/CAM-technology and laboratory manual production techniques. MATRIALS AND METHODS: and study design Each 10 composite inlays were fabricated using different types of production techniques: CAD/CAM- technology (A), the new inlay system (B), plaster model after alginate impression (C) or silicone impression (D). The inlays were adapted into a metal tooth and silicone replicas of the cement gaps were made and measured. Statistical analysis was performed using ANOVA and Tukey's test. Results and Statistics In group A the biggest marginal gaps (174.9μm ± 106.2μm) were found. In group B the gaps were significantly smaller (119.5 μm ± 90.6 μm) than in group A (p=0.035). Between groups C (64.6 μm ± 68.0μm) and D (58.2 μm ± 61.7 μm) no significant differences could be found (p=0.998), but the gaps were significantly smaller compared with group B. Conclusion Chairside manufacturing of composite inlays resulted in better marginal precision than CAD/CAM technology. In comparison to build restorations in a laboratory, the new system is a timesaving and inexpensive alternative. Nevertheless, production of indirect composite restorations in the dental laboratory showed the highest precision.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Internal and Marginal Fit of Modern Indirect Class II Composite Inlays

Introduction: This in vitro study investigates the marginal and internal fit of indirect class II composite restorations. Two different processes for chair-side restorations were compared. In group A, the restorations were fabricated using CAD/CAM technology (Cerec, Sirona, Germany, Bernsheim) and in group B they were made by hand (GrandioSO Inlay System, VOCO GmbH, Germany, Cuxhaven). Methods:...

متن کامل

Ceramic Inlays versus Composite Inlays

Acid etching and filled acrylic materials have been generating great interest in the past few years because of increased public demand for esthetic restorations and alternatives to amalgam. Composite resin and ceramic inlays, which use adhesive bonding, were introduced to make possible toothcolored restorations. The physical properties of composite resin restorations, and their poor wear resist...

متن کامل

Comparison of the marginal adaptation of direct and indirect composite inlay restorations with optical coherence tomography

OBJECTIVE The purpose of the study was to use the photonic imaging modality of optical coherence tomography (OCT) to compare the marginal adaptation of composite inlays fabricated by direct and indirect techniques. MATERIAL AND METHODS Class II cavities were prepared on 34 extracted human molar teeth. The cavities were randomly divided into two groups according to the inlay fabrication techni...

متن کامل

Marginal Adaptation of Indirect Composite, Glass-Ceramic Inlays and Direct Composite: An In Vitro Evaluation

OBJECTIVE This experimental in vitro study compared marginal adaptation of indirect composite, glass-ceramic inlays and direct composite. MATERIALS AND METHODS Seventy-five recently extracted human molars were randomly divided into three groups (n=25) and mesio-occluso-distal cavities with the same dimensions were prepared in the teeth. Indirect composite and glass-ceramic inlays were fabrica...

متن کامل

Marginal Adaptation and Microleakeage of Directly and Indirectly Made Fiber Reinforced Composite Inlays

AIM This study evaluated in vitro microleakage of inlays made by direct or indirect techique with or without fiber reinforced composite (FRC) substructure. MATERIALS AND METHODS Standardized mesio-occlusal cavities were prepared and restored using direct-technique with composite resin only or FRC-composite resin, and indirect technique with laboratory composite only or FRC-laboratory composit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of paediatric dentistry : official journal of European Academy of Paediatric Dentistry

دوره 17 3  شماره 

صفحات  -

تاریخ انتشار 2016