Comparative evaluation of three different treponemal enzyme immunoassays for syphilis.
نویسندگان
چکیده
BACKGROUND To reduce human errors and subjective interpretation, automation is currently a trend. However, replacing any tests with automation must first be validated. OBJECTIVE Evaluate the EIA tests performance characteristics of three commercially available enzyme immunoassays; Enzygnost Syphilis (Dade Behring Ltd), Syphilis EIA 480 (Newmarket Laboratory Ltd) and ICE* Syphilis (Abbott Murex). MATERIAL AND METHOD Three thousand and fifty-five serum samples were obtained from all workers who came for physical check ups before working abroad at the physical check-up unit of the out- patient department at Siriraj Hospital between February and August, 2001. Serum specimens known to be positive with VDRL and TPHA or FTA-ABS tests were included in the present study. RESULTS Of all the samples, 2953 were from workers who came for physical check ups; 102 were selected from known specimens positive with the Venereal Disease Research Laboratory test (VDRL) and Treponema Pallidum Hemagglutination Assay (TPHA) or Fluorescent Treponemal Antibody ABSorption (FTA-ABS) test. A true positive result was determined when the sample was reactive either with two out of three enzyme immunoassays and TPHA or FTA-ABS, or both TPHA and FTA-ABS. A true negative result was determined when the aforementioned were absent. The sensitivity and specificity of Enzygnost Syphilis, Syphilis EIA 480 and ICE* Syphilis were 100% and 97.89%, 100% and 99.59%, and 99.1% and 99.76%, respectively. The results suggest that the specificity of Enzygnost Syphilis is the lowest among these three enzyme immunoassays; the price is also the cheapest. The decision to replace an existing test depends not only on the performance characteristics but also on other factors such as cost effectiveness, turnaround time, instrument maintenance, etc. The present study shows performance characteristics, whereas an economic evaluation is only briefly mentioned regarding a hospital's decision in making test selection. CONCLUSION Among the three commercial kits, the specificity of Enzygnost Syphilis was the lowest. However, the replacement of any existing test depends greatly on the purpose of the individual laboratory whereas performance characteristics will provide us with an appropriate economic evaluation.
منابع مشابه
Usefulness of IgM-specific enzyme immunoassays for serodiagnosis of syphilis: comparative evaluation of three different assays.
OBJECTIVES IgM antibodies are usually the first to be produced during treponemal infection. Three commercially available enzyme immunoassays (EIA) for detection of IgM antibodies against Treponema pallidum were evaluated. METHODS Results of the Anti-Treponema-pallidum-ELISA (IgM; Euroimmun), Pathozyme Syphilis M Capture (Omega Diagnostics) and recomWell Treponema IgM (Mikrogen) were compared ...
متن کاملEvaluation of the Vitros Syphilis TPA chemiluminescence immunoassay as a first-line method for reverse syphilis screening.
We report here the results of the diagnostic performances of Vitros Syphilis TPA (a chemiluminescence treponemal assay) compared with those of two treponemal enzyme immunoassays and of traditional versus reverse syphilis algorithms. Ease of use, automation, and high throughput make the Vitros Syphilis TPA assay a good choice for syphilis screening in high-volume laboratories.
متن کاملEuropium Nanoparticle-Based High Performing Immunoassay for the Screening of Treponemal Antibodies
Treponema pallidum subspecies pallidum (Tp) is the causative agent of syphilis which mainly spreads through sexual contact, blood transfusion and perinatal route. In order to curtail the spread of the infection and to clinically manage the disease, timely, accurate and reliable diagnosis is very important. We have developed an immunoassay for the detection of treponemal antibodies in human seru...
متن کاملEvaluation of the Captia enzyme immunoassays for detection of immunoglobulins G and M to Treponema pallidum in syphilis.
Two new enzyme-linked immunosorbent assays (ELISA), one for the measurement of immunoglobulin G (IgG) (Captia Syphilis-G) and one for the measurement of IgM (Captia Syphilis-M), were evaluated for detecting antibodies to Treponema pallidum. Serum samples from 169 patients, 96 with various stages of untreated syphilis, 63 with treated syphilis, and 10 who were noninfected, were investigated. All...
متن کاملNovel Treponema pallidum serologic tests: a paradigm shift in syphilis screening for the 21st century.
The mainstay of diagnosis for Treponema pallidum infections is based on nontreponemal and treponemal serologic tests. Many new diagnostic methods for syphilis have been developed, using specific treponemal antigens and novel formats, including rapid point-of-care tests, enzyme immunoassays, and chemiluminescence assays. Although most of these newer tests are not yet cleared for use in the Unite...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the Medical Association of Thailand = Chotmaihet thangphaet
دوره 89 6 شماره
صفحات -
تاریخ انتشار 2006