Nonuniqueness in dual-energy CT.

نویسنده

  • Zachary H Levine
چکیده

PURPOSE The goal is to determine whether dual-energy computed tomography (CT) leads to a unique reconstruction using two basis materials. METHODS The beam-hardening equation is simplified to the single-voxel case. The simplified equation is rewritten to show that the solution can be considered to be linear operations in a vector space followed by a measurement model which is the sum of the exponential of the coordinates. The case of finding the concentrations of two materials from measurements of two spectra with three photon energies is the simplest non-trivial case and is considered in detail. RESULTS Using a material basis of water and bone, with photon energies of 30 keV, 60 keV, and 100 keV, a case with two solutions is demonstrated. CONCLUSIONS Dual-energy reconstruction using two materials is not unique as shown by an example. Algorithms for dual-energy, dual-material reconstructions need to be aware of this potential ambiguity in the solution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study

  In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...

متن کامل

Comparing 511 keV Attenuation Maps Obtained from Different Energy Mapping Methods for CT Based Attenuation Correction of PET Data

Introduction:  The  advent  of  dual-modality  PET/CT  scanners  has  revolutionized  clinical  oncology  by  improving lesion localization and facilitating treatment planning for radiotherapy. In addition, the use of  CT images for CT-based attenuation correction (CTAC) decreases the overall scanning time and creates  a noise-free  attenuation  map  (6map).  CTAC  methods  include  scaling,  s...

متن کامل

Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography

Background: This study set out to evaluate the utility of cerebrovascular virtual non-contrast (VNC) scans. Materials and Methods: Conventional non-contrast (CNC) and dual-energy computed tomography angiography (DE-CTA) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified les...

متن کامل

Dual-Energy CT with Fast-kVp Switching and Its Applications in Orthopedics

Dual-energy CT is an imaging technique that has been known and extensively studied for many decades [1-8]. However, due to various technical challenges, only recently has dual-energy CT imaging become a reality. Recent advances in CT scanner technologies have generated a renewed interest in dual-energy CT [9-14], which has led to the commercialization of dual-energy CT systems available for rou...

متن کامل

Dual-Energy CT: New Horizon in Medical Imaging.

Dual-energy CT has remained underutilized over the past decade probably due to a cumbersome workflow issue and current technical limitations. Clinical radiologists should be made aware of the potential clinical benefits of dual-energy CT over single-energy CT. To accomplish this aim, the basic principle, current acquisition methods with advantages and disadvantages, and various material-specifi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 44 9  شماره 

صفحات  -

تاریخ انتشار 2017