OBJECTIVES We sought to assess the prevalence of secondary right-to-left circulatory shunt (RLS) in patients undergoing transcatheter closure of patent foramen ovale (PFO) as detected by power M-mode transcranial Doppler (TCD) and intracardiac echocardiography. BACKGROUND Prevalence of residual RLS in late follow-up after PFO closure may be as high as 34%. Other cardiac and noncardiac sources of RLS may coexist and obscure PFO closure evaluation. METHODS Eighty-eight patients who underwent transcatheter PFO closure to prevent recurrent paradoxical cerebral embolism between June 2005 and December 2006 were evaluated for a secondary source of RLS. Before device deployment, a sizing balloon was inflated in the PFO tunnel and agitated saline contrast was injected into the inferior vena cava. Clinically significant secondary RLS was defined as >10 embolic tracks on TCD at rest or immediately after calibrated (40 mm Hg), sustained (10 s) respiratory strain, with corresponding negative color-flow Doppler. Late residual RLS was evaluated in all patients with TCD and transthoracic echocardiography (mean: 192 days; 95% confidence interval [CI]: 161 to 223 days). RESULTS The sample (n = 84) was 59% female, age 49 +/- 14 years. Seventeen patients (20%; 95% CI: 11.7 to 28.8) had secondary RLS during balloon occlusion. At late follow-up (n = 66), 13 of 14 (93%) patients with secondary RLS and 23 of 52 (44%) patients without secondary RLS had residual RLS (p = 0.002). CONCLUSIONS This is the first report to systematically assess the prevalence of secondary RLS in patients undergoing PFO closure. Residual RLS detected by TCD may be due to secondary RLS, which may have implications for clinical outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Absence of recurrent stroke after percutaneous closure of patent foramen ovale despite residual right-to-left cardiac shunt assessed by transcranial Doppler.

BACKGROUND Percutaneous transcatheter closure of patent foramen ovale has been proposed to prevent recurrent strokes in young adults. Contrast transcranial Doppler ultrasonography provides a functional, semiquantitative evaluation of right-to-left cardiac shunt. AIMS To evaluate the efficacy of percutaneous closure of patent foramen ovale in suppressing right-to-left shunt (assessed using tra...

متن کامل

The prevalence of right to left shunt in chronic obstructive pulmonary disease patients with increased pulmonary hypertension

Background: One of the important etiologies for cryptogenic stroke is paradoxical embolization secondary to Patent Foramen Ovale (PFO). Foramen ovale can secondarily reopen due to Pulmonary Arterial Hypertension (PAH) which is common among the older age. PAH is known as a frequent and life threatening complication of COPD. The aim of this study was to determine the prevalence of PFO between COP...

متن کامل

Doppler-device Not known Quantification Cerebral microemboli during carotid artery endarterectomy and angioplasty with stenting Right to left shunt in cryptogenic stroke: TCD vs. TEE Author

Patent foramen ovale is frequently associated with embolic cerebrovascular accidents. The diagnosis of patent foramen ovale (PFO) is easier since the advent of transesophageal echocardiography but is invasive and does not allow to detect extracardiac RLS. Contrast transcranial Doppler ultrasound enables the detection of the passage of a contrast material injected into a peripheral vein to the c...

متن کامل

Diagnosis and quantification of patent foramen ovale. Which is the reference technique? Simultaneous study with transcranial Doppler, transthoracic and transesophageal echocardiography.

INTRODUCTION AND OBJECTIVES Patent foramen ovale (PFO) is the most common cause of cryptogenic stroke in patients younger than 55. Transesophageal echocardiography (TEE) has been accepted as the reference diagnostic technique. The purpose of this study was to compare the accuracy of transthoracic echocardiography (TTE), TEE and transcranial Doppler (TCD) in the diagnosis and quantification of p...

متن کامل

Foramen Ovale in Stroke Patients

Background and Purpose: The prevalence of a patent foramen ovale has been shown to be increased in patients with ischemic stroke. Transesophageal echocardiography, transthoracic echocardiography, and transcranial Doppler examination with contrast injection can all be used to search for a patent foramen ovale. We compared the accuracy of these techniques for identifying a patent foramen ovale in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 2 6  شماره 

صفحات  -

تاریخ انتشار 2009