Evaluation of the SVOne: A Handheld, Smartphone-Based Autorefractor

نویسندگان

  • Kenneth J. Ciuffreda
  • Mark Rosenfield
چکیده

PURPOSE The SVOne is a portable Hartmann-Shack wavefront aberrometer that can be attached to a smartphone to determine the refractive error of the eye objectively. The aim of the present study was to compare the findings of the SVOne with retinoscopy, subjective refraction, and two commercially available autorefractors (Topcon KR-1W and Righton Retinomax-3). METHODS Refractive error was assessed both with and without cycloplegia in 50 visually normal, young adults using the five techniques described above. Further, to assess repeatability of the instruments, the entire procedure was repeated in a subgroup of 10 subjects. All data were analyzed in terms of power vectors (M, J0, and J45). RESULTS No significant difference was observed between the mean values of M (spherical equivalent) for the different techniques. However, a significantly higher mean value of precyclopegic J0 was recorded for the SVOne, which also had the highest limits of agreement for both the J0 and J45 astigmatic components. Retinoscopy and subjective refraction showed the best repeatability (in terms of M values) for precycloplegic and postcycloplegic measurements, respectively. High and significant linear correlations were observed between the subjective findings and the other four techniques. CONCLUSIONS The results indicate that the SVOne handheld aberrometer provides measurements of refractive error in normal, young individuals that are not significantly different from other subjective and objective procedures. This instrument is valuable for vision screenings, as well as examinations taking place outside the clinical office. It may also serve as an adjunct in the standard optometric examination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the SVOne Handheld Autorefractor in a Pediatric Population.

PURPOSE The SVOne is a portable, Hartmann-Shack wavefront aberrometer, which can be attached to a smartphone to determine the refractive error of the eye objectively. Previous results have shown the device to provide measurements equivalent to those of standard clinical techniques in young, healthy adults. The aim of the present study was to compare the findings of the SVOne with retinoscopy, s...

متن کامل

Design and Clinical Evaluation of a Handheld Wavefront Autorefractor.

PURPOSE To introduce a novel autorefractor design that is intended to be manufacturable at low cost and evaluate its performance in measuring refractive errors. METHODS We developed a handheld, open-view autorefractor (the "QuickSee" [QS]) that uses a simplified approach to wavefront sensing that forgoes moving parts and expensive components. Adult subjects (n = 41) were recruited to undergo ...

متن کامل

Design and Evaluation of a Smartphone-Based Application to Manage the Treatment of People with Heart Failure

Abstract Aims: Patients with heart failure need training and support regarding the drug diet, how to use medications, diet, activities, and appropriate action when symptoms occur. The aim of this study was to design and evaluate a smartphone-based application to manage the treatment of people with heart failure. Materials and Methods: In this developmental-applied study with the software design...

متن کامل

Clinical evaluation of refraction using a handheld wavefront autorefractor in young and adult patients.

PURPOSE To determine the accuracy of measurement by the SureSight autorefractor (software version 2.0) and the influence of accommodation. SETTING Pediatric Section, Department of Ophthalmology, University of Hamburg, Hamburg, Germany. METHODS In a series of comparative measurements, autorefractor readings were compared with cycloplegic retinoscopy in 195 eyes of 108 patients (1 to 81 years...

متن کامل

Smartphone-based application for training outpatient cardiac rehabilitation: Design and usability evaluation

Introduction: Due to the increasing trend of heart diseases and their complications, programs such as cardiac rehabilitation can reduce the complications and faster recovery of patients. Therefore, the aim of this study was to design and evaluate the usability of smartphone-based application for training outpatient cardiac rehabilitation. Materials and Methods: This applied-developmental study ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 92  شماره 

صفحات  -

تاریخ انتشار 2015