A kinematic comparison of fixed- and mobile-bearing knee replacements.

نویسندگان

  • H P Delport
  • S A Banks
  • J De Schepper
  • J Bellemans
چکیده

Mobile-bearing posterior-stabilised knee replacements have been developed as an alternative to the standard fixed- and mobile-bearing designs. However, little is known about the in vivo kinematics of this new group of implants. We investigated 31 patients who had undergone a total knee replacement with a similar prosthetic design but with three different options: fixed-bearing posterior cruciate ligament-retaining, fixed-bearing posterior-stabilised and mobile-bearing posterior-stabilised. To do this we used a three-dimensional to two-dimensional model registration technique. Both the fixed- and mobile-bearing posterior-stabilised configurations used the same femoral component. We found that fixed-bearing posterior stabilised and mobile-bearing posterior-stabilised knee replacements demonstrated similar kinematic patterns, with consistent femoral roll-back during flexion. Mobile-bearing posterior-stabilised knee replacements demonstrated greater and more natural internal rotation of the tibia during flexion than fixed-bearing posterior-stabilised designs. Such rotation occurred at the interface between the insert and tibial tray for mobile-bearing posterior-stabilised designs. However, for fixed-bearing posterior-stabilised designs, rotation occurred at the proximal surface of the bearing. Posterior cruciate ligament-retaining knee replacements demonstrated paradoxical sliding forward of the femur. We conclude that mobile-bearing posterior-stabilised knee replacements reproduce internal rotation of the tibia more closely during flexion than fixed-bearing posterior-stabilised designs. Furthermore, mobile-bearing posterior-stabilised knee replacements demonstrate a unidirectional movement which occurs at the upper and lower sides of the mobile insert. The femur moves in an anteroposterior direction on the upper surface of the insert, whereas the movement at the lower surface is pure rotation. Such unidirectional movement may lead to less wear when compared with the multidirectional movement seen in fixed-bearing posterior-stabilised knee replacements, and should be associated with more evenly applied cam-post stresses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wear Comparison of Fixed vs. Mobile Bearing Total Knee Replacements

INTRODUCTION: The debate between fixed-bearing and mobile-bearing systems continues due to the lack of clinical evidence showing survivorship of one to be superior to the other [1,2]. Delport et al report similar tibiofemoral kinematic patterns with respect to axial rotation during flexion and also femorotibial translation [3]. Conversely, Huang et al show a significant difference between the t...

متن کامل

Comparison of Wear in Fixed and Mobile Bearing Knee Designs

Ultra High Molecular Weight Polyethylene (UHMWPE) remains the only bearing surface of choice in total knee replacements (TKR). While excellent medium term results can be found for knee replacements at ten years, there remains concerns about wear debris induced osteolysis in the longer term, particularly in young and more active patients. It has been shown previously that the wear of fixed beari...

متن کامل

Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing.

We compared the early results of mobile-bearing knee prosthesis with fixed-bearing knee prosthesis in 16 patients who had one-stage, sequential, bilateral replacements. In each patient, a Low Contact Stress (LCS, Depuy) rotating-platform prosthesis was inserted in one side, and an Anatomic Modular Knee (AMK, Depuy) posterior-stabilised prosthesis was inserted in the other side. The same surgica...

متن کامل

Mobile-bearing knee replacement: concepts and results.

In summary, if TKRs are to be performed in patients who are younger and more active than those who had the initial procedures in the 1970s and 1980s, better wear performance is imperative for long-term durability, especially if surgeons continue to consider the versatility associated with modular knee-replacement systems to be a necessity. At least with some designs, including the Oxford knee a...

متن کامل

Gait analysis of fixed bearing and mobile bearing total knee prostheses during walking: do mobile bearings offer functional advantages?

BACKGROUND Limited previous findings have detailed biomechanical advantages following implantation with mobile bearing (MB) prostheses after total knee replacement (TKR) surgery during walking. The aim of this study was to compare three dimensional spatiotemporal, kinematic, and kinetic parameters during walking to examine whether MBs offer functional advantages over fixed bearing (FB) designs....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 88 8  شماره 

صفحات  -

تاریخ انتشار 2006