Conventional transbronchial needle aspiration (TBNA) using 19-gauge needles can obtain larger histological specimens for hilar-mediastinal diagnosis. A new 19-gauge eXcelon needle was introduced in Taiwan in July 2012. We prospectively enrolled patients with hilar-mediastinal lesions and pathology results of suspected benign origin or lymphoproliferative processes, to perform TBNA using a 19-gauge eXcelon needle, between July 2012 and December 2012. The results were compared with historical control of TBNA using a WANG MW-319 needle between January 2011 and June 2012. The procedure was performed by the same pulmonologist, and rapid on-site cytologic evaluation was used. The 19-gauge eXcelon needle was used in nine patients with 15 lymph nodes aspirated, with a mean diameter of 23.3 ± 10.7 mm. The mean number of needle passes was 2.7 ± 1.4, with a diagnostic accuracy of 77.8%. The MW-319 needle was used in 12 patients with 18 lymph nodes aspirated, with a mean diameter of 21.3 ± 5.7 mm. The mean number of needle passes was 2.2 ± 0.4, with a diagnostic accuracy of 75.0%. Neither technical nor major clinical complications were noted in either group. We concluded that the 19-gauge eXcelon needle was as safe and effective as the MW-319 needle. A more adequate specimen could be obtained and fewer needle passes were required with the MW-319 needle, although the difference did not reach significance.
منابع مشابه
Comparison of Inferior Dental Nerve Block Injections in Child Patients Using 30-Gauge and 27-Gauge Short Needles
Introduction: The purpose of the present study was to record their pain sensation and to assess children`s reaction objectively and subjectively while receiving dental local anesthesia with 27- and 30-gauge needles. Methods: Forty children (24 boys and 16 girls) participated in this study. A random double-blinded crossover design was used so that each child served as his or her own control, rec...
متن کامل[Clinical utility of transbronchial needle aspiration of mediastinal lymph nodes in the diagnosis of sarcoidosis in stages I and II].
OBJECTIVE To analyze the individual and combined diagnostic yield and clinical utility of transbronchial needle aspiration and transbronchial biopsy in the histologic diagnosis of sarcoidosis in stages I and II. PATIENTS AND METHODS We performed a prospective study enrolling all the patients admitted to our hospital between July 2001 and June 2006 with mediastinal lymph nodes of a diameter of...
متن کاملComparison of inferior dental nerve block injections in child patients using 30-gauge and 25-gauge short needles.
Thirty-gauge needles are generally not recommended by dental schools, yet many dentists use them. Thin needles (30 gauge) can aspirate blood, have similar deflection to thick needles (25 gauge), and resist breakage. Measurable clinical differences between inferior dental block injections using 25-gauge or 30-gauge short needles for children is addressed in this research paper. Random allocation...
متن کاملBeneficial effects of pulmonary rehabilitation in adult asthma.
in the few studies published they vary between 22% and 91%. In this retrospective case study analysis, the prevalence of LPD was low (46.2%), with a low pretest probability in some cases, which could have hampered sensitivity. According the Chest guideline about EBUS-TBNA, trials evaluating needle size were reviewed and both 21 and 22 gauge needles are considered adequate. The role of 19 gauge ...
متن کاملEndoscopic ultrasound-guided tissue sampling: How can we improve the results?
Endoscopic ultrasound (EUS) enables a gastroenterologist to sample the masses of the middle and inferior mediastinum, which are adjacent to the esophagus; cystic or solid lesions of the pancreas, which are adjacent to the stomach and duodenum; and perirectal lesions. Needles used for EUS sampling include aspiration (19, 20, and 22 Gauge) or core biopsy needles (ProCore and Trucut) (19, 20, and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thoracic cancer
دوره 7 2 شماره
صفحات -
تاریخ انتشار 2016