Automated Determination of Serum Glutamic Oxalacetic and Glutamic Pyruvic Transaminase.
نویسندگان
چکیده
The determination of serum glutamic oxalacetic and glutamic pyruvic transaminase has been simplified by the use of automated analysis. The flow diagrams, concentration of reagents, and calculation of the color unit in terms of the Karmen unit are shown for 2,4-dinitrophenylhydrazine and 6-benzamido-4-methoxy-m -toluidine diazonium chloride as the reacting dyes. Advantages of both methods are compared and discussed.
منابع مشابه
Technical improvements in measurement of L -aspartate:2-oxoglutarate aminotransferase activity in serum by diazonium salt coupling.
3. Jacobs, W. L. W., Gamrna-glutamyl transpeptidase in disease of the liver, cardiovascularsystem and diabetesmellitus.Clin. Chim. Acta 38,419(1972). 4. Karmen, A., A note on the spectrophotometric assay of glutamic oxalacetic transaminase in human blood serum. J. Clin. Invest. 34, 131 (1955). 5. Wroblewski, F., and La Due, J. S., Serum glutamic pyruvic transaminase in cardiac and hepatic disea...
متن کاملValue of the Jirgl flocculation test in the diagnosis of jaundice.
The Jirgl flocculation test has been compared with the combination of the thymol reactions and serum alkaline phosphatase determination recommended by Maclagan in the investigation of 68 patients with jaundice. The test was found to be of value in distinguishing biliary obstruction from other causes of jaundice, but failed to distinguish between extrahepatic and intrahepatic biliary obstruction...
متن کاملCorrelation between triglycerides and glutamic-pyruvic transaminase in men on high-fat diets.
Of eight young men on high.fat diets (60% of caloric intake) for 42 days, four developed serum glutamic-pyruvic tra nsaminase concentrations greater than normal, while lactic dehydrogenase, glutamic-oxalacetic transaminase, and alkaline and acid phosphatases were within the normal range. Serum triglyceride levels were also within the normal range, but significant correlations between serum trig...
متن کاملElectrophoresis of Glutamic Oxalacetic Transaminase in Serum, Beef Heart, and Liver Homogenates on Cellulose Acetate.
‘THE RECENT DEVELOPMENT of a new colorimetric procedure (TransAc*), for the determination of serum glutamic oxalacetic transaminase utilizing the diazonium salt, 6-benzamido-4-methoxy-m-toluidine diazonium chloride, as the color developer with a specificity for oxalacetic acid, prompted the following experiments. Determination of glutamic oxalacetic transaminase activities were performed accord...
متن کاملAnalysis of pleural effusions from rats exposed to high concentrations of oxygen.
Pleural effusions from rats exposed to high concentrations of oxygen for periods of up to 96 hr. were analyzed by routine clinical chemical methods.When compared to control rat serum, the values for glutamic oxalacetic transaminase, the albumin/ globulin ratio, potassium, and inorganic phosphate were higher in the pleural effusions. Alkaline phosphatase, total protein, albumin, and calcium valu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 10 شماره
صفحات -
تاریخ انتشار 1964