Photoacoustic section imaging with an integrating cylindrical detector

نویسندگان

  • Sibylle Gratt
  • Klaus Passler
  • Robert Nuster
  • Guenther Paltauf
چکیده

A piezoelectric detector with a cylindrical shape is investigated for photoacoustic section imaging. Images are acquired by rotating a sample in front of the cylindrical detector. With its length exceeding the size of the imaging object, it works as an integrating sensor and therefore allows reconstructing section images with the inverse Radon transform. Prior to the reconstruction the Abel transform is applied to the measured signals to improve the accuracy of the image. A resolution of about 100 µm within a section and of 500 µm between sections is obtained. Additionally, a series of images of a zebra fish is shown.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact removal in photoacoustic section imaging by combining an integrating cylindrical detector with model-based reconstruction.

Photoacoustic section imaging reveals optically absorbing structures within a thin slice of an object. It requires measuring acoustic waves excited by absorption of short laser pulses with a cylindrical acoustic lens detector rotating around the object. Owing to the finite detector size and its limited depth of focus, various artifacts arise, seen as distortions within the imaging slice and cro...

متن کامل

Photoacoustic Section Imaging with Integrating Detectors

Photoacoustic section imaging is a method for visualizing structures with optical contrast in selected layers of an extended object. In order to avoid resolution limitations that are due to commonly used ultrasound detectors of finite size, we propose the use of extended, integrating cylindrical elements for focusing the acoustic detection into the selected section. Two imaging methods based on...

متن کامل

Optimising the detection parameters for deep tissue photoacoustic imaging

For deep tissue photoacoustic imaging, piezoelectric ultrasound detectors with large element sizes (>1mm) and relatively low centre frequencies (<5MHz) are generally used, as they can provide the required high sensitivity to achieve imaging depths of several centimetres. However, these detectors are generally not optimised in terms of element size and bandwidth. To identify these parameters in ...

متن کامل

Dual wavelength laser diode excitation source for 2D photoacoustic imaging

Photoacoustic methods can be used to make spatially resolved spectroscopic measurements of blood oxygenation when using a multiwavelength excitation source, such as an OPO system. Since these excitation sources are usually expensive and bulky, an alternative is to use laser diodes. A fibre coupled laser diode excitation system has been developed, providing two wavelengths, 850 and 905nm, each c...

متن کامل

Piezoelectric line detector array for photoacoustic tomography

Photoacoustic tomography relies on a dense coverage of the surface surrounding the imaged object with ultrasound sensors in order to enable an accurate reconstruction. A curved arrangement of integrating line sensors is proposed that is able to acquire data for a linear projection image of the absorbed energy density distribution in the object. Upon rotation of the object relative to the array,...

متن کامل