A Current Differential Line Protection Using a Synchronous Reference Frame Approach
نویسندگان
چکیده
This paper presents a new approach for a current differential protection of the transmission lines. This approach is based on the Park transformation or ABC-dqo transformation. Using the ABC-dqo transformation the three phase quantities are transformed into a synchronous rotating reference frame. In this way, the line currents of the three phase system are measured and transformed into three dc components. So, immunity to problems such as sampling misalignment and time delay of the communication channel will be improved. Several test results are presented in order to show the effectiveness of the proposed approach.
منابع مشابه
Power Swings Damping Improvement with STATCOM and SMES Based on the Direct Lyapunov Method
In this paper a comprehensive approach is presented to improve power swings damping based on direct Lyapunov method. The approach combines superconducting magnetic energy storage (SMES) system with static synchronous compensator (STATCOM). Considering the energy absorption/injection ability of SMES, in transient states the combination exchanges both active and reactive powers with power system....
متن کاملModified Impedance-Based OOS Protection Based on On-Line Thévenin Equivalent Estimation
In this paper, a novel approach based on the Thévenin tracing is presented to modified conventional impedance-based out-of-step (OOS) protection. In conventional approach, the OOS detection is done by measuring positive sequence impedance. However, the measured impedance may be change due to different factors such as capacitor bank switching and reactive power compensators that it can cause the...
متن کاملImproving the performance of UPQC under unbalanced and distortional load conditions: A new control method
This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...
متن کاملImpedance-Based Out-of-Step Protection of Generator in the Presence of STATCOM
This paper presents a novel impedance-based approach for out-of-step (OOS) protection of a synchronous generator. The most popular and commonly used approaches for detecting OOS conditions are based on the measurement of positive sequence impedance at relay location. However, FACTS devices change the measured impedance value and thus disrupt the performance of impedance-based relay function. In...
متن کاملA Practical Approach to Harmonic Compensation in Electrical Power Systems – Using Shunt Active Power Filter
The Shunt active power filters are used in power systems for the compensation of harmonic currents generated for non linear loads. A reference current estimation method for control of SAPF using a digital filter based synchronous reference frame theory is presented. To extract the fundamental component of source current, the synchronous reference frame (SRF) theory is suitable because of its ea...
متن کامل