A new volume selective sequence for single-shot diffusion-weighting by the trace of the diffusion tensor

نویسندگان

  • J. Valette
  • M. Ahmed Ghaly
  • D. Le Bihan
  • F. Lethimonnier
چکیده

Introduction Diffusion-weighted (DW) spectroscopy is a unique tool for exploring the intracellular micro-environment in vivo [1]. In living systems, diffusion is generally anisotropic, since biological membranes may exhibit some anisotropic orientation, and signal attenuation generally depends on the orientation of the gradients relative to the cellular orientation, diffusion being characterized by the diffusion tensor D. Measuring the trace of the diffusion tensor Dav=1/3×(Dxx+Dyy+Dzz) may be particularly interesting. Indeed, since the trace of a tensor is invariant under rotation of the reference frame, Dav is independent of cellular orientation within the gradient frame. This might allow the characterization of intrinsic diffusion properties of the intracellular microenvironment without bias induced by the cellular orientation. In this work, a volume selective DW-sequence allowing single-shot measurement of Dav is proposed. Cross-terms between diffusion gradients and other gradients (including background gradients) are all cancelled out. In addition, an adiabatic version (similar to the LASER sequence [2], with additional diffusion gradients) is derived, which provides partial immunity to cross-terms. Proof of concept is performed on anisotropic tissues (ex vivo chicken muscle), by varying tissue orientation and intra-voxel shim. Theory Cancellation of cross-terms: Let’s consider the sequence in Fig. 1A, consisting in a non-selective 90° excitation followed by two identical slice selection blocks, each block consisting in a 180° pulse with a slice selection gradient Gslice, surrounded by spoilers Gspoil. Refocusing is assumed to occur at the center of the pulse. Diffusion-weighting is achieved using two gradient lobes of duration δ and amplitude Gdiff with opposite polarities, located outside the two slice selection blocks and separated by the delay Δ. A B0 inhomogeneity gradient G0 is also considered. As shown graphically in Fig. 1, the particular symmetry of the sequence results in a null integral for kdiffkspoil, kdiffkslice and kdiffk0, i.e. cross-terms between diffusion gradients and other gradients cancel out: signal is only weighted by the diagonal term of D in the direction of Gdiff. Single-shot Dav measurement: Following the above analysis performed for a single diffusion block, it is straightforward to derive a volume selective DW-sequence made of one non-selective 90° pulse followed by three successive orthogonal blocks built by circular permutation of the gradient axes, such as shown on Fig. 2. Because the phase induced by diffusion gradients is refocused (kdiff=0) at the end of each block, these blocks are temporally isolated from each other and diffusion-weighting arising from the three blocks simply adds up:

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isotropic Steady State Diffusion Weighted Imaging

Introduction Steady-state diffusion-weighted imaging enables high-SNR, high-resolution diffusion images of brain and is potentially effective in the diagnosis of stroke location [1]. However, white matter anisotropic tissue contrast can mask out a real stroke location. In order to get rid of the anisotropic effect of diffusion, the whole diffusion tensor is acquired and its trace is derived. Al...

متن کامل

Diffusion tensor mapping of the human brain using single-shot line scan imaging.

A recently developed single-shot line scan imaging technique for diffusion measurements (Finsterbusch and Frahm, Magn Reson Med 1999;42:772-778) was extended to full diffusion tensor mapping of the human brain. Because the sequence acquires stimulated echoes from individual columns of magnetization ("lines"), the approach is affected neither by spatial aliasing when studying inner volumes nor b...

متن کامل

Analysis of partial volume effects in diffusion-tensor MRI.

The diffusion tensor is currently the accepted model of diffusion in biological tissues. The measured diffusion behavior may be more complex when two or more distinct tissues with different diffusion tensors occupy the same voxel. In this study, a partial volume model of MRI signal behavior for two diffusion-tensor compartments is presented. Simulations using this model demonstrate that the con...

متن کامل

In vivo diffusion tensor imaging of rat spinal cord at 7 T.

In vivo diffusion tensor imaging of normal rat spinal cord was performed using a multi-segmented, blipped EPI sequence at 7 T field strength. At high diffusion weighting, the signal exhibited a non-monoexponential decay that was fitted to a biexponential function, associated with the fast and slow components of diffusion in the cord tissue, using a nonlinear regression analysis along with a con...

متن کامل

Diffusion-weighted imaging of the fetal brain in vivo.

A method of performing diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI) of the fetal brain in utero is proposed. The major difficulty of performing diffusion imaging in utero is the presence of motion. By modifying conventional single-shot spin-echo echo-planar DWI with a short repetition time sequence, a sequence that performs DWI and DTI within a breath-hold of the mother (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009