Pulse pressure variation and volume responsiveness during acutely increased pulmonary artery pressure: an experimental study

نویسندگان

  • Fritz Daudel
  • David Tüller
  • Stefanie Krähenbühl
  • Stephan M Jakob
  • Jukka Takala
چکیده

INTRODUCTION We found that pulse pressure variation (PPV) did not predict volume responsiveness in patients with increased pulmonary artery pressure. This study tests the hypothesis that PPV does not predict fluid responsiveness during an endotoxin-induced acute increase in pulmonary artery pressure and right ventricular loading. METHODS Pigs were subjected to endotoxemia (0.4 microg/kg/hour lipopolysaccharide), followed by volume expansion, subsequent hemorrhage (20% of estimated blood volume), retransfusion, and additional stepwise volume loading until cardiac output did not increase further (n = 5). A separate control group (n = 7) was subjected to bleeding, retransfusion, and volume expansion without endotoxemia. Systemic hemodynamics were measured at baseline and after each intervention, and PPV was calculated offline. Prediction of fluid-challenge-induced stroke volume increase by PPV was analyzed using receiver operating characteristic (ROC) curves. RESULTS Sixty-eight volume challenges were performed in endotoxemic animals (22 before and 46 after hemorrhage), and 51 volume challenges in the controls. Endotoxin infusion resulted in an acute increase in pulmonary artery and central venous pressure and a decrease in stroke volume (all P < 0.05). In endotoxemia, 68% of volume challenges before hemorrhage increased the stroke volume by > 10%, but PPV did not predict fluid responsiveness (area under the ROC curve = 0.604, P = 0.461). After hemorrhage in endotoxemia, stroke volume increased in 48% and the predictive value of PPV improved (area under the ROC curve for PPV = 0.699, P = 0.021). In controls after hemorrhage, stroke volume increased in 67% of volume challenges and PPV was a predictor of fluid responsiveness (area under the ROC curve = 0.790, P = 0.001). CONCLUSIONS Fluid responsiveness cannot be predicted with PPV during acute pulmonary hypertension in porcine endotoxemia. Even following severe hemorrhage during endotoxemia, the predictive value of PPV is marginal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulse-pressure variation and hemodynamic response in patients with elevated pulmonary artery pressure: a clinical study

INTRODUCTION Pulse-pressure variation (PPV) due to increased right ventricular afterload and dysfunction may misleadingly suggest volume responsiveness. We aimed to assess prediction of volume responsiveness with PPV in patients with increased pulmonary artery pressure. METHODS Fifteen cardiac surgery patients with a history of increased pulmonary artery pressure (mean pressure, 27 +/- 5 mm H...

متن کامل

A simple physiologic algorithm for managing hemodynamics using stroke volume and stroke volume variation: physiologic optimization program.

Intravascular volume status and volume responsiveness continue to be important questions for the management of critically ill or injured patients. Goal-directed hemodynamic therapy has been shown to be of benefit to patients with severe sepsis and septic shock, acute lung injury and adult respiratory distress syndrome, and for surgical patients in the operating room. Static measures of fluid st...

متن کامل

The respiratory change in preejection period: a new method to predict fluid responsiveness.

The accuracy and clinical utility of preload indexes as bedside indicators of fluid responsiveness in patients after cardiac surgery is controversial. This study evaluates whether respiratory changes (Delta) in the preejection period (PEP; DeltaPEP) predict fluid responsiveness in mechanically ventilated patients. Sixteen postcoronary artery bypass surgery patients, deeply sedated under mechani...

متن کامل

Respirophasic carotid artery peak velocity variation as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease.

BACKGROUND We studied respirophasic variation in carotid artery blood flow peak velocity (ΔVpeak-CA) measured by pulsed wave Doppler ultrasound as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease. METHODS Forty patients undergoing elective coronary artery bypass surgery were enrolled. Subjects were classified as responders if stroke volume i...

متن کامل

Pulse pressure variation predicts fluid responsiveness following coronary artery bypass surgery.

STUDY OBJECTIVE To determine whether the degree of pulse pressure variation (PPV) and systolic pressure variation (SPV) predict an increase in cardiac output (CO) in response to volume challenge in postoperative patients who have undergone coronary artery bypass grafting (CABG), and to determine whether PPV is superior to SPV in this setting. DESIGN AND SETTING This was a prospective clinical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2010