Prospective 3-dimensional computed tomography segmentation of the pericardiac right phrenic nerve in the setting of atrial fibrillation ablation.
نویسندگان
چکیده
A 58-year-old man was referred for catheter ablation of symptomatic persistent atrial fibrillation without structural heart disease. Informed consent and local committee approval were obtained. He underwent preprocedural cardiac computed tomography (CT) angiography after administration of intravenous contrast for evaluation of left atrium and pulmonary vein (PV) anatomy. The pericardiac course of the right phrenic nerve (RPN) was delineated on the CT imaging by an experienced radiologist, either using direct RPN visual-ization or inferring the position of the right pericardiophrenic bundle by visualizing the right pericardiophrenic artery when RPN could not be directly seen. A new CT imaging sequence was created containing the original CT images with the path of the RPN overwritten by a 5-pixel wide 3-dimensional curved line at 900 HU value in attenuation to facilitate seg-mentation of the RPN in the electrophysiology laboratory. Three-dimensional reconstruction of the CT images in the new sequence was performed using the CARTO 3 software (Biosense Webster, Diamond Bar, CA). The cardiac chambers , PVs, and the RPN were segmented using the applied specific attenuation threshold. Detailed contact electroanatomic mapping of the left atrium, PVs, right atrium, and superior vena cava was performed using the fast anatomic mapping feature of CARTO 3, and the fast anatomic mapping was then merged with the CT images using CARTOMERGE. Differential output pacing (10, 30, and 50 mA at 2-ms pulse width) was performed along the course of the RPN in right superior PV, left atrium, superior vena cava, and right atrium. RPN capture was assessed by manual palpation of the patient's right hypochondrium for diaphragmatic contraction during pacing. Noncapture and capture points were tagged on the electroanatomic mapping using different colors depending on RPN's threshold. RPN capture points were marked in the cardiac chambers adjacent to the merged RPN CT image, and capture threshold correlated visually with the actual distance between capture points and the RPN (Figure). In general, capture points at 10 mA were located ≤5 to 10 mm from the RPN, whereas capture points at 50 mA were located ≤10 to 20 mm from the RPN. Noncapture points at 50 mA were distant from the RPN. Ablations surrounding the right PVs were not performed where the RPN could be captured at any output. PV isolation using circumferential antral ablation was subsequently performed without complications. RPN injury is a highly symptomatic but uncommon complication of right superior PV isolation or superior vena cava ablation. …
منابع مشابه
[Phrenic nerve identification with cardiac multidetector computed tomography].
Cryoballoon ablation of the pulmonary veins is a new technique that has proven useful in preventing paroxysmal and persistent atrial fibrillation recurrence. One of the most serious complications of this method is right phrenic nerve palsy. The usefulness of multidetector computed tomography to locate the right phrenic nerve and artery and predict the risk of phrenic nerve palsy during cryoabla...
متن کاملImaging before cryoablation of atrial fibrillation: is phrenic nerve palsy predictable?
AIMS Multidetector computerized tomography (MDCT) with improved temporal and spatial resolution is one of the most commonly used non-invasive tests for evaluation of pulmonary veins (PVs) and adjacent structures before cryoablation of atrial fibrillation (AF). Identification of spatial neighbouring of phrenic nerves is important to decrease likelihood of phrenic nerve palsy (PNP). The purpose o...
متن کاملInitial experience of cryoballoon catheter ablation for atrial fibrillation in Hong Kong.
OBJECTIVE. To report the initial experience in using cryoballoon catheter ablation in the treatment of atrial fibrillation in Hong Kong. DESIGN. Single-centre, prospective case series. SETTING. Regional hospital, Hong Kong. PATIENTS. Sixteen patients (mean age, 55 years; standard deviation, 14 years; 11 males) with paroxysmal (n=12) or persistent (n=4) atrial fibrillation. INTERVENTIONS. Pulmon...
متن کاملProtecting the right phrenic nerve during catheter ablation: Techniques and anatomical considerations
Introduction Phrenic nerve injury is a recognized complication of catheter ablation procedures for atrial and ventricular arrhythmias. The posterolateral right atrium (RA) is a common site of origin for atrial tachycardias (AT), but ablation in this region can be hazardous because of the proximity of the right phrenic nerve (RPN). Proximity to the nerve may be identified by capture during pacin...
متن کاملPhrenic Nerve Injury After Catheter Ablation of Atrial Fibrillation
UNLABELLED Phrenic Nerve Injury (PNI) has been well studied by cardiac surgeons. More recently it has been recognized as a potential complication of catheter ablation with a prevalence of 0.11 to 0.48 % after atrial fibrillation (AF) ablation. This review will focus on PNI after AF ablation. Anatomical studies have shown a close relationship between the right phrenic nerve and it's proximity to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 7 3 شماره
صفحات -
تاریخ انتشار 2014