Assessment of cytotoxicity using electric cell-substrate impedance sensing: concentration and time response function approach.
نویسندگان
چکیده
This paper describes a simple and convenient method to measure the concentration and time response function f (C,t) of cells exposed to a toxicant by electric cell-substrate impedance sensing. Attachment and spreading of fibroblastic V79 cells cultured on small gold electrodes precoated with fibronectin were detected as electrical resistance changes. With this method, chemical cytotoxicity was easily screened by observing the response function of attached cells in the presence of inhibitor. The cytotoxicities of three test models, cadmium chloride, sodium arsenate, and benzalkonium chloride, were quantified by measuring the percentage inhibition as a function of the inhibitor concentration. The half-inhibition concentration, the required concentration to achieve 50% inhibition, derived from the response function agreed well with the results obtained using the standard neutral red assay.
منابع مشابه
On-line monitoring of cell growth and cytotoxicity using electric cell-substrate impedance sensing (ECIS).
An on-line and continuous technique based on electric cell-substrate impedance sensing (ECIS) was developed for measuring the concentration and time response function of fibroblastic V79 cells exposed to mercury chloride and 1,3,5-trinitrobenzene (TNB). Attachment, spreading and proliferation of V79 fibroblastic cells cultured on a microarray of small gold electrodes precoated with fibronectin ...
متن کاملAssessment of cytotoxicity by emerging impedance spectroscopy.
An on-line and continuous technique based on electric cell substrate impedance sensing (ECIS) was developed for measuring the concentration and time response function of fibroblastic V79 cells exposed to toxicants. Mercury chloride (HgCl(2)), cadmium chloride (CdCl(2)), benzalkonium chloride (BAK), sodium arsenate (Na(2)HAsO(4)), and trinitrobenzene (TNB) were used as five test models. The firs...
متن کاملOnline Measurement of Real-Time Cytotoxic Responses Induced by Multi-Component Matrices, such as Natural Products, through Electric Cell-Substrate Impedance Sensing (ECIS).
Natural products are complex matrices of compounds that are prone to interfere with the label-dependent methods that are typically used for cytotoxicity screenings. Here, we developed a label-free Electric Cell-substrate Impedance Sensing (ECIS)-based cytotoxicity assay that can be applied in the assessment of the cytotoxicity of natural extracts. The conditions to measure the impedance using E...
متن کاملInterdependence of initial cell density, drug concentration and exposure time revealed by real-time impedance spectroscopic cytotoxicity assay.
We investigated the combined effect of the initial cell density (12,500, 35,000, 75,000, and 100,000 cells cm(-2)) and concentration of the anti-cancer drug doxorubicin on HeLa cells by performing time-dependent cytotoxicity assays using real-time electrochemical impedance spectroscopy. A correlation between the rate of cell death and the initial cell seeding density was found at 2.5 μM doxorub...
متن کاملReal-time monitoring primary cardiomyocyte adhesion based on electrochemical impedance spectroscopy and electrical cell-substrate impedance sensing.
The cell-substrate distance is a direct indicator of cell adhesion to extracellular matrix which is indispensable in cell culture. A real-time monitoring approach can provide a detailed profile of cell adhesion, so that enables the detecting of adhesion-related cell behavior. In this work, we report a novel real-time impedance-based method to record the adhesion profile of cardiomyocyte, overco...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 74 22 شماره
صفحات -
تاریخ انتشار 2002