Determining the Uncertainty of X-Ray Absorption Measurements

نویسنده

  • Gary S. Wojcik
چکیده

X-ray absorption (or more properly, x-ray attenuation) techniques have been applied to study the moisture movement in and moisture content of materials like cement paste, mortar, and wood. An increase in the number of x-ray counts with time at a location in a specimen may indicate a decrease in moisture content. The uncertainty of measurements from an x-ray absorption system, which must be known to properly interpret the data, is often assumed to be the square root of the number of counts, as in a Poisson process. No detailed studies have heretofore been conducted to determine the uncertainty of x-ray absorption measurements or the effect of averaging data on the uncertainty. In this study, the Poisson estimate was found to adequately approximate normalized root mean square errors (a measure of uncertainty) of counts for point measurements and profile measurements of water specimens. The Poisson estimate, however, was not reliable in approximating the magnitude of the uncertainty when averaging data from paste and mortar specimens. Changes in uncertainty from differing averaging procedures were well-approximated by a Poisson process. The normalized root mean square errors decreased when the x-ray source intensity, integration time, collimator size, and number of scanning repetitions increased. Uncertainties in mean paste and mortar count profiles were kept below 2 % by averaging vertical profiles at horizontal spacings of 1 mm or larger with counts per point above 4000. Maximum normalized root mean square errors did not exceed 10 % in any of the tests conducted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On study of X-ray absorption and properties of dispersion of W, MoS2 and B4C particles in high density polyethylene

Shielding radiation from both x-rays and gamma-rays is important for personnel in medical fields e.g. interventional radiology, nuclear power stations, and other inspection facilities where radiation is involved. Lead is known for its effective shielding property against these high energy radiations, however heaviness and toxicity are its main drawback. In this study effectiveness of non-lead p...

متن کامل

Structural and Optical Properties of Gold Nanoparticles Formed by Wet-Chemical Method

Our aim in this work is the synthesis and study optical and structural properties of gold nanoparticles.Gold (III) chloride trihydratewas taken as metal precursor, ascorbic acid at the presence of an appropriate amount of NaOH as reducing agent and polyvinylpyrrolidonek-30 (PVP K-30) as a stabilizing and capping agent. The reaction was performed in high-speed stirring rate at room temperature.S...

متن کامل

Structural and Optical Properties of Gold Nanoparticles Formed by Wet-Chemical Method

Our aim in this work is the synthesis and study optical and structural properties of gold nanoparticles.Gold (III) chloride trihydratewas taken as metal precursor, ascorbic acid at the presence of an appropriate amount of NaOH as reducing agent and polyvinylpyrrolidonek-30 (PVP K-30) as a stabilizing and capping agent. The reaction was performed in high-speed stirring rate at room temperature.S...

متن کامل

Evaluation of X-Ray Absorption by Ointment Containing Bismuth Oxide Nanoparticles in Radiology Staff

Introduction: The effects of X-rays on carcinogens have been proven in recent years. Today, lead is used in many devices such as lead covers, thyroid protectors to protect the body against x-rays. But this equipment contains many disadvantages such as, Toxicity, High weight and Lack of flexibility. Today, newer methods, such as semi-solid skin care products (cream, ointment), a...

متن کامل

An improvement to the full-foil mapping technique for high accuracy measurement of X-ray mass attenuation coefficients

The limiting uncertainty in recent high accuracy measurements of the mass attenuation coefficient is the measurement of the integrated column density. An improvement in the design of the absorption foil holder is described which reduces the integrated column density uncertainty. The new design allows the edges of the foil to be more accurately mapped by the X-ray beam by reducing the largest so...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 109  شماره 

صفحات  -

تاریخ انتشار 2004