Chemical vapor detection using a capacitive micromachined ultrasonic transducer.

نویسندگان

  • Hyunjoo J Lee
  • Kwan Kyu Park
  • Mario Kupnik
  • O Oralkan
  • Butrus T Khuri-Yakub
چکیده

Distributed sensing of gas-phase chemicals using highly sensitive and inexpensive sensors is of great interest for many defense and consumer applications. In this paper we present ppb-level detection of dimethyl methylphosphonate (DMMP), a common simulant for sarin gas, with a ppt-level resolution using an improved capacitive micromachined ultrasonic transducer (CMUT) as a resonant chemical sensor. The improved CMUT operates at a higher resonant frequency of 47.7 MHz and offers an improved mass sensitivity of 48.8 zg/Hz/μm(2) by a factor of 2.7 compared to the previous CMUT sensors developed. A low-noise oscillator using the CMUT resonant sensor as the frequency-selective device was developed for real-time sensing, which exhibits an Allan deviation of 1.65 Hz (3σ) in the presence of a gas flow; this translates into a mass resolution of 80.5 zg/μm(2). The CMUT resonant sensor is functionalized with a 50-nm thick DKAP polymer developed at Sandia National Laboratory for dimethyl methylphosphonate (DMMP) detection. To demonstrate ppb-level detection of the improved chemical sensor system, the sensor performance was tested at a certified lab (MIT Lincoln Laboratory), which is equipped with an experimental chemical setup that reliably and accurately delivers a wide range of low concentrations down to 10 ppb. We report a high volume sensitivity of 34.5 ± 0.79 pptv/Hz to DMMP and a good selectivity of the polymer to DMMP with respect to dodecane and 1-octanol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Residual Stress and Young’s Modulus Measurement of Capacitive Micromachined Ultrasonic Transducer Membranes

AbstmctMembranes supported by posts are used as vibrating elements of capacitive micromachined ultrasonic transducers (CMUTs). The residual stress built up during the fabrication process determines the transducer properties such as resonance frequency, collapse voltage, and gap distance. Hence, it is important t o evaluate and control the stress in thin film CMUT membranes. The residual stress ...

متن کامل

Improved Modeling and Design of Microphones Using Radio Frequency Detection with Capacitive Micromachined Ultrasonic Transducers

Broadband acoustic sensing, over several decades of frequency, has traditionally been difficult to achieve. An alternative approach to conventional condenser microphones is to use capacitive micromachined ultrasonic transducer (CMUT) membranes with a sensitive radio frequency (RF) detection method. Since the resonant frequency of a typical CMUT membrane is several megahertz, the membrane respon...

متن کامل

Capacitive micromachined ultrasonic transducers for robotic sensing applications

Ultrasonic ranging is the most common method used in robotic systems for distance or proximity sensing. The heart of the method is an ultrasonic transducer that emits and detects ultrasound. There are mainly two types of transducers existing in the market today; piezoelectric and electrostatic. In this paper, we propose the use of a new type of transducer, which is capacitive micromachined ultr...

متن کامل

Capacitive Micromachined Ultrasonic Transducers (CMUTs) for Underwater Imaging Applications

A capacitive micromachined ultrasonic transducer structure for use in underwater imaging is designed, fabricated and tested in this paper. In this structure, a silicon dioxide insulation layer is inserted between the top electrodes and the vibration membrane to prevent ohmic contact. The capacitance-voltage (C-V) characteristic curve shows that the transducer offers suitable levels of hysteresi...

متن کامل

Surface Micromachined Capacitive Ultrasonic Immersion Transducers - Micro Electro Mechanical Systems, 1998. MEMS 98. Proceedings., The Eleventh Annual International W

Major steps used in fabricating surface micromachined capacitive ultrasonic immersion transducers are investigated in this paper. Such steps include membrane formation and cavity sealing under vacuum. Three transducer membrane structures are evaluated: a nitride membrane with an LTO sacrificial layer; a polysilicon membrane with an LTO sacrificial layer; and a nitride membrane with a polysilico...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 83 24  شماره 

صفحات  -

تاریخ انتشار 2011