Amperometric Hydrogen Peroxide Biosensor Based on Immobilization of Hemoglobin on a Glassy Carbon Electrode Modified with Fe3O4/Chitosan Core-Shell Microspheres
نویسندگان
چکیده
Novel magnetic Fe(3)O(4)/chitosan (CS) microspheres were prepared using magnetic Fe(3)O(4) nanoparticles and the natural macromolecule chitosan. Then, using an easy and effective hemoglobin (Hb) immobilization method, an innovative biosensor with a Fe(3)O(4)/CS-Hb-Fe(3)O(4)/CS "sandwich" configuration was constructed. This biosensor had a fast (less than 10 s) response to H(2)O(2) and excellent linear relationships were obtained in the concentration range of 5.0 × 10(-5) to 1.8 × 10(-3) M and 1.8 × 10(-3) to 6.8 × 10(-3) M with a detection limit of 4.0 × 10(-6) M (s/n = 3) under the optimum conditions. The apparent Michaelis-Menten constant K(m) was 0.29 mM and it showed the excellent biological activity of the fixed Hb. Moreover, the biosensor had long-time stability and good reproducibility. The method was used to determine H(2)O(2) concentration in real samples.
منابع مشابه
A Biosensor Based on Immobilization of Horseradish Peroxidase in Chitosan Matrix Cross-linked with Glyoxal for Amperometric Determination of Hydrogen Peroxide
An amperometric biosensor for hydrogen peroxide (H2O2) was developed via an easy and effective enzyme immobilization method with the “sandwich” configuration: ferrocene-chitosan: HRP: chitosan-glyoxal using a glassy carbon electrode as the basic electrode. In order to prevent the loss of immobilized HRP under optimized conditions, the biosensor surface was cross-linked with glyoxal. Ferrocene w...
متن کاملHighly sensitive and selective uric acid biosensor based on direct electron transfer of hemoglobin-encapsulated chitosan-modified glassy carbon electrode.
A uric acid biosensor based on the direct electron transfer of a hemoglobin-encapsulated chitosan-modified glassy carbon electrode was developed for a highly sensitive and selective analysis in urine samples. The modified electrode was prepared by the encapsulation of hemoglobin and uricase in a chitosan matrix. The hydrogen peroxide produced from the catalytic oxidation of uric acid by uricase...
متن کاملComparison between Amperometric and Chemiluminescence methods in detection and dosimetry of cobalt-60 gamma ray emission
Background: Hydrogen peroxide (H2O2), produced by gamma ray irradiation to watery solution, was used as an analytical parameter for dosimetry of cobalt-60 (60Co) radiation. Materials and Methods: Detection of the produced H2O2 was carried out using two methods: an amperometric biosensor fabricated by immobilization of anthraquinone 2-carboxylic acid modified horseradish peroxidase on glassy car...
متن کاملAn electrochemical biosensor for fructosyl valine for glycosylated hemoglobin detection based on core-shell magnetic bionanoparticles modified gold electrode.
A high-performance amperometric fructosyl valine (FV) biosensor was developed, based on immobilization of fructosyl amino-acid oxidase (FAO) on core-shell magnetic bionanoparticles modified gold electrode. Chitosan was used to introduce amino groups onto the surface of core-shell magnetic bionanoparticles (MNPs). With FAO as an enzyme model, a new fructosyl valine biosensor was fabricated. The ...
متن کاملAmperometric Biosensor Based on Diamine Oxidase/Platinum Nanoparticles/Graphene/Chitosan Modified Screen-Printed Carbon Electrode for Histamine Detection
This work describes the development and optimization studies of a novel biosensor employed in the detection and quantification of histamine in freshwater fish samples. The proposed biosensor is based on a modified carbon screen-printed electrode with diamineoxidase, graphene and platinum nanoparticles, which detects the hydrogen peroxide formed by the chemical process biocatalysed by the enzyme...
متن کامل