Measurement of the wave-front aberration of the eye by a fast psychophysical procedure.

نویسندگان

  • J C He
  • S Marcos
  • R H Webb
  • S A Burns
چکیده

We used a fast psychophysical procedure to determine the wave-front aberrations of the human eye in vivo. We measured the angular deviation of light rays entering the eye at different pupillary locations by aligning an image of a point source entering the pupil at different locations to the image of a fixation cross entering the pupil at a fixed location. We fitted the data to a Zernike series to reconstruct the wave-front aberrations of the pupil. With this technique the repeatability of the measurement of the individual coefficients was 0.019 micron. The standard deviation of the overall wave-height estimation across the pupil is less than 0.3 micron. Since this technique does not require the administration of pharmacological agents to dilate the pupil, we were able to measure the changes in the aberrations of the eye during accommodation. We found that administration of even a mild dilating agent causes a change in the aberration structure of the eye.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The spatially resolved refractometer.

PURPOSE To investigate factors controlling the aberrations of the eye, including accommodation, wavelength, and the apodization of the optics of the eye by cone directional selectivity. METHODS We constructed a new implementation of the Spatially Resolved Refractometer (SRR). This is an instrument, based on the Scheiner principle, that allows the rapid psychophysical measurement of the comple...

متن کامل

Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement

Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...

متن کامل

Monochromatic aberrations in the accommodated human eye

The wave-front aberration of the human eye was measured for eight subjects using a spatially resolved refractometer (a psychophysical ray-tracing test). The eyes were undilated and presented with accommodative stimuli varying from 0 to -6 diopters. Monochromatic wave-front aberrations tend to increase with increasing levels of accommodation, although there are substantial individual variations ...

متن کامل

Effect of the polarization on ocular wave aberration measurements.

Measurement of the eye's wave aberrations has become fairly standard in recent years. However, most studies have not taken into account the possible influence of the polarization state of light on the wave aberration measurements. The birefringence properties of the eye's optical components, in particular corneal birefringence, can be expected to have an effect on the wave aberration estimates ...

متن کامل

Closed-loop adaptive optics in the human eye.

We have developed a prototype apparatus for real-time closed-loop measurement and correction of aberrations in the human eye. The apparatus uses infrared light to measure the wave-front aberration at 25 Hz with a Hartmann-Shack sensor. Defocus is removed by a motorized optometer, and higher-order aberrations are corrected by a membrane deformable mirror. The device was first tested with an arti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Optical Society of America. A, Optics, image science, and vision

دوره 15 9  شماره 

صفحات  -

تاریخ انتشار 1998