The use of capacitive-mesh output couplers for optically pumped far-infrared molecular lasers has been extended throughout the far-infrared spectrum, between 42 microm and 1.2 mm, and the optimum grid constants have been found for several lines. At shorter wavelengths, performance has been improved by the use of a novel hybrid capacitive-mesh hole output coupler.
منابع مشابه
Terahertz Behavior of Optical Components and Common Materials
As short range, ground based, surveillance systems operating at terahertz frequencies continue to evolve, increasing attention is being directed towards the behavior of dielectric materials at terahertz frequencies as well as the behavior of optical components used to control terahertz radiation. This work provides an overview of several terahertz optical components such as frequency selective ...
متن کاملVery Short Far-Infrared Pulses from Optically Pumped CH30H/D, CHsF, and HCOOH Lasers Using an EO-Switched
متن کامل
Pressure effects on the frequency of continuous-wave optically pumped far-infrared lasers.
The frequency of the 170.6-microm cw CH(3)OH optically pumped laser emission has been remeasured at different pressures without observing the pressure shift observed by Lawandy and Koepf [Opt. Lett. 5, 383 (1980)]. The far-infrared frequency was synthesized with two stabilized CO(2) lasers. No measurable pressure shift over the operating pressure range of the laser was observed, and the frequen...
متن کاملFabrication and optimization of uniform output couplers for far-infrared lasers.
An improved technique for the fabrication of uniform output couplers for far-infrared lasers has been developed. The technique includes a process for uniformly removing material from the back side of the coupler's substrate to tune the coupler's reflectivity precisely to the specified value for a particular laser line. Depending on the condition of the coupler after use, it can be retuned to an...
متن کاملApplication of Advanced Millimeter/ Far-infrared Sources to Collective Thomson Scattering Plasma Diagnostics
The application of advanced millimeter/far infrared sources to substantially improve the effectiveness of collective Thomson scattering plasma diagnostics is discussed. Gyrotrons, C02 lasers and far infrared lasers which are optically pumped with CO 2 laser radiation can now provide important new capabilities in terms of combined high peak power and high average power, fine frequency tunability...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics letters
دوره 3 1 شماره