Microwave-induced thermoacoustic tomography: reconstruction by synthetic aperture.

نویسندگان

  • D Feng
  • Y Xu
  • G Ku
  • L V Wang
چکیده

We have applied the synthetic-aperture method to linear-scanning microwave-induced thermoacoustic tomography in biological tissues. A nonfocused ultrasonic transducer was used to receive thermoacoustic signals, to which the delay-and-sum algorithm was applied for image reconstruction. We greatly improved the lateral resolution of images and acquired a clear view of the circular boundaries of buried cylindrical objects, which could not be obtained in conventional linear-scanning microwave-induced thermoacoustic tomography based on focused transducers. Two microwave sources, which had frequencies of 9 and 3 GHz, respectively, were used in the experiments for comparison. The 3 GHz system had a much larger imaging depth but a lower signal-noise ratio than the 9 GHz system in near-surface imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of acoustic heterogeneities on transcranial brain imaging with microwave-induced thermoacoustic tomography.

The effects of acoustic heterogeneities on transcranial brain imaging with microwave-induced thermoacoustic tomography were studied. A numerical model for calculating the propagation of thermoacoustic waves through the skull was developed and experimentally examined. The model takes into account wave reflection and refraction at the skull surfaces and therefore provides improved accuracy for th...

متن کامل

Scanning microwave-induced thermoacoustic tomography: signal, resolution, and contrast.

Scanning thermoacoustic tomography was explored in the microwave region of the electromagnetic spectrum. Short microwave pulses were used to induce acoustic waves by thermoelastic expansion in biological tissues. Cross sections of tissue samples were imaged by a linear scan of the samples while a focused ultrasonic transducer detected the time-resolved thermoacoustic signals. Based on the micro...

متن کامل

Thermoacoustic tomography with correction for acoustic speed variations.

Thermoacoustic tomography (TAT) is a technique that measures microwave-induced thermoacoustic waves at the boundary of biological tissue and generates images of internal microwave absorption distributions from the measurements. Existing reconstruction algorithms for TAT are based on the assumption that the acoustic properties in the tissue are homogeneous. Biological tissue, however, has hetero...

متن کامل

Imaging of high-intensity focused ultrasound-induced lesions in soft biological tissue using thermoacoustic tomography.

An imaging technology, thermoacoustic tomograpy (TAT), was applied to the visualization of high-intensity focused ultrasound (HIFU)-induced lesions. A single, spherically focused ultrasonic transducer, operating at a central frequency of approximately 4 MHz, was used to generate a HIFU field in fresh porcine muscle. Microwave pulses from a 3-GHz microwave generator were then employed to generat...

متن کامل

Pulsed-microwave-induced thermoacoustic tomography: filtered backprojection in a circular measurement configuration.

Our study on pulsed-microwave-induced thermoacoustic tomography in biological tissues is presented. A filtered backprojection algorithm based on rigorous theory is used to reconstruct the cross-sectional image from a thermoacoustic measurement in a circular configuration that encloses the sample under study. Specific details describing the measurement of thermoacoustic waves and the implementat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 28 12  شماره 

صفحات  -

تاریخ انتشار 2001