Failure of annexin-based apoptosis imaging in the assessment of antiangiogenic therapy effects
نویسندگان
چکیده
BACKGROUND Molecular apoptosis imaging is frequently discussed to be useful for monitoring cancer therapy. We demonstrate that the sole assessment of therapy effects by apoptosis imaging can be misleading, depending on the therapy effect on the tumor vasculature. METHODS Apoptosis was investigated by determining the uptake of Annexin Vivo by optical imaging (study part I) and of 99 mTc-6-hydrazinonicotinic [HYNIC]-radiolabeled Annexin V by gamma counting (study part II) in subcutaneous epidermoid carcinoma xenografts (A431) in nude mice after antiangiogenic treatment (SU11248). Optical imaging was performed by optical tomography (3D) and 2D reflectance imaging (control, n = 7; therapy, n = 6). Accumulation of the radioactive tracer was determined ex vivo (control, n = 5; therapy, n = 6). Tumor vascularization was investigated with an optical blood pool marker (study part I) and contrast-enhanced ultrasound (both studies). Data were validated by immunohistology. RESULTS A significantly higher apoptosis rate was detected in treated tumors by immunohistological terminal deoxynucleotidyl transferase-mediated dUTP nick end labeling staining (area fraction: control, 0.023 ± 0.015%; therapy, 0.387 ± 0.105%; P < 0.001). However, both 2D reflectance imaging using Annexin Vivo (control, 13 ± 15 FI/cm2; therapy, 11 ± 7 FI/cm2) and gamma counting using 99 mTc-HYNIC-Annexin V (tumor-to-muscle ratio control, 5.66 ± 1.46; therapy, 6.09 ± 1.40) failed in showing higher accumulation in treated tumors. Optical tomography even indicated higher probe accumulation in controls (control, 81.3 ± 73.7 pmol/cm3; therapy, 27.5 ± 34.7 pmol/cm3). Vascularization was strongly reduced after therapy, demonstrated by contrast-enhanced ultrasound, optical imaging, and immunohistology. CONCLUSIONS The failure of annexin-based apoptosis assessment in vivo can be explained by the significant breakdown of the vasculature after therapy, resulting in reduced probe/tracer delivery. This favors annexin-based apoptosis imaging only in therapies that do not severely interfere with the vasculature.
منابع مشابه
Synthesis, Radiolabeling, and Biological Evaluation of Peptide LIKKPF Functionalized with HYNIC as Apoptosis Imaging Agent
Introduction: A noninvasive method of detecting exposure of phosphatidylserine (PS) on the external surface of the plasma membrane such as nuclear imaging could assist the diagnosis and therapy of apoptosis related pathologies. The most studied imaging agent for apoptosis is Annexin V so far. Because of limitations of Annexin V other agents have been introduced such as small peptides and molecu...
متن کاملSynthesis, Radiolabeling, and Biological Evaluation of Peptide LIKKPF Functionalized with HYNIC as Apoptosis Imaging Agent
Introduction: A noninvasive method of detecting exposure of phosphatidylserine (PS) on the external surface of the plasma membrane such as nuclear imaging could assist the diagnosis and therapy of apoptosis related pathologies. The most studied imaging agent for apoptosis is Annexin V so far. Because of limitations of Annexin V other agents have been introduced such as small peptides and molecu...
متن کاملPreparation and biodistribution study of 99mTc-EC-Annexin-SPIO as a tracer of radiation induced apoptosis in mice model
Introduction: Apoptosis is a major consequence of ionizing radiation in proliferative tissues and quantification of the apoptotic cells could be helpful for noninvasive assessment and estimation of the radiation absorbed dose. Annexin V conjugated with super paramagnetic iron oxide nanoparticles (ANX-SPIO) is a biological probe for detection of apoptotic cells using magnetic resonance imaging. ...
متن کامل99mTc-HYNIC-Annexin A5 in Oncology: Evaluating Efficacy of Anti-Cancer Therapies
Evaluation of efficacy of anti-cancer therapy is currently performed by anatomical imaging (e.g., MRI, CT). Structural changes, if present, become apparent 1-2 months after start of therapy. Cancer patients thus bear the risk to receive an ineffective treatment, whilst clinical trials take a long time to prove therapy response. Both patient and pharmaceutical industry could therefore profit fro...
متن کاملCardioprotective C-kit+ Bone Marrow Cells Attenuate Apoptosis after Acute Myocardial Infarction in Mice - In-vivo Assessment with Fluorescence Molecular Imaging
Cardiomyocyte loss via apoptosis plays a crucial role in ventricular remodeling following myocardial infarction (MI). Cell-based therapy approaches using bone marrow derived c-kit⁺ pluripotent cells may attenuate apoptosis following ischemic injury. We therefore thought to examine the early course of apoptosis following myocardial infarction - in-vivo - and non-invasively determine the effect o...
متن کامل