Simulation and Development of a Mock Circulation Loop with Variable Compliance
نویسنده
چکیده
Heart disease is attributed as the highest cause of death in the world. Although this could be alleviated by heart transplantation, there is a chronic shortage of donor hearts and so mechanical solutions are being considered. Currently, many Ventricular Assist Devices (VADs) are being developed worldwide in an effort to increase life expectancy and quality of life for end stage heart failure patients. Current pre-clinical testing methods for VADs involve laboratory testing using Mock Circulation Loops (MCLs), and in vivo testing in animal models. The research and development of highly accurate MCLs is vital to the continuous improvement of VAD performance. The first objective of this study was to develop and validate a mathematical model of a MCL. This model could then be used in the design and construction of a variable compliance chamber to improve the performance of an existing MCL as well as form the basis for a new miniaturised MCL. An extensive review of literature was carried out on MCLs and mathematical modelling of their function. A mathematical model of a MCL was then created in the MATLAB/SIMULINK environment. This model included variable features such as resistance, fluid inertia and volumes (resulting from the pipe lengths and diameters); compliance of Windkessel chambers, atria and ventricles; density of both fluid and compressed air applied to the system; gravitational effects on vertical columns of fluid; and accurately modelled actuators controlling the ventricle contraction. This model was then validated using the physical properties and pressure and flow traces produced from a previously developed MCL. A variable compliance chamber was designed to reproduce parameters determined by the mathematical model. The function of the variability was achieved by controlling the transmural pressure across a diaphragm to alter the compliance of the system. An initial prototype was tested in a previously developed MCL, and a variable level of arterial compliance was successfully produced; however, the complete range of compliance values required for accurate physiological representation was not able to be produced with this initial design. ii The mathematical model was then used to design a smaller physical mock circulation loop, with the tubing sizes adjusted to produce accurate pressure and flow traces whilst having an appropriate frequency response characteristic. The development of the mathematical model greatly assisted the general design of an in vitro cardiovascular device test rig, while the variable compliance chamber allowed simple and real-time manipulation of MCL compliance to allow …
منابع مشابه
Simulation and Experimental Verification of Closed Loop Operation of Buck / Boost DC-DC Converter with Soft Switching
A major problem in an isolated DC/DC converters operating at high switching frequencies is the attendant switching losses in the semiconductor devices. This can be reduced by introducing either zero-voltage switching (ZVS) or zero-current switching (ZCS) of the semiconductor switches. This paper deals with the simulation, design, fabrication and experimental evaluation of a novel soft-switching...
متن کاملDesign and Simulation of Double Loop Control for Power Converter Fed Variable Speed DC Drive
متن کامل
Quantification the Effect of Ageing on Characteristics of the Photoplethysmogram Using an Optimized Windkessel Model
Background: With increasing age, some changes appeared in specifications of vessels which including dimensions and elasticity in their. The changes in parameters such as resistance, inertance and compliance vessels appear and eventually changes in the environmental pulse releases are in circulation. These changes clearly appear in specification of photoplethysmogram particularly in the size and...
متن کاملModeling and Simulation of Variable Frequency Pump Control Fatigue Test Machine
High-speed maglev train is considered an ideal vehicle in the 21st Century, as an important part of the train, the travel mechanism bears and delivers a variety of vertical and horizontal alternating load in operation, it affects the operation safety of the train directly, so key components of the travel mechanism should under fatigue strength test by fatigue test machine.The paper proposed a v...
متن کاملSimulation and enhancement of a cardiovascular device test rig
(2010) Simulation and enhancement of a cardiovascular device test rig. Cardiovascular assist devices are tested in mock circulation loops (MCLs) prior to animal and clinical testing. These MCLs rely on characteristics such as pneumatic parameters to create pressure and flow, and pipe dimensions to replicate the resistance, compliance and fluid inertia of the natural cardiovascular system. A mat...
متن کامل