Response of CR-39 to Heat Exposure
نویسندگان
چکیده
As a nuclear track detector, CR-39 (polyallyl diglycol carbonate) is used to reveal the products of fusion reactions. Positioned around the OMEGA target chamber, pieces of CR-39 absorb and are damaged by ejected particles. The plastic is then etched in NaOH solution at 80°C for 6 hours, resulting in the formation of nuclear tracks visible under a digital microscope. The etching process also reveals background noise, speculated in part to be the result of exposure to heat during shipment between suppliers and laboratories. To determine the effects of heat exposure on data analysis, pieces of CR-39 were exposed to high temperatures for various times. Heated pieces were then exposed to protons of known energies using the particle accelerator at SUNY Geneseo. Each exposed piece was etched and compared to a control. Pieces were found to oscillate between a visibly cloudy and clear appearance as a function of time exposed to high temperatures. This property was measured and quantified via reflectance and transmission of light. Furthermore, it was observed that exposure to temperatures above 100°C resulted in inaccurate data collection as etch rate and therefore track size were affected. This combination of results is an indication that current tests of the purity of CR-39 before use on OMEGA may not be sufficient.
منابع مشابه
Effect of Zinc Sulfate and Organic Chromium Supplementation on the Performance, Meat Quality and Immune Response of Japanese Quails under Heat Stress Conditions
This study was conducted to investigate the effects of different levels of zinc sulfate and chromium picolinate on the performance, immune response and meat quality of Japanese quails under heat stress condition. The birds (n = 540; 7-d-old) were randomly assigned to 9 treatment groups consisting of 3 replicates of 20 birds each in a 3 × 3 factorial arrangement of treatments [zinc (0, 40, 80 mg...
متن کاملCalculating CR-39 Response to Radon in Water Using Monte Carlo Simulation
Introduction CR-39 detectors are widely used for Radon and progeny measurement in the air. In this paper, using the Monte Carlo simulation, the possibility of using the CR-39 for direct measurement of Radon and progeny in water is investigated. Materials and Methods Assuming the random position and angle of alpha particle emitted by Radon and progeny, alpha energy and angular spectrum that arri...
متن کاملExperimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum
Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produce H, C and O recoils, as well as (n, α) reaction. These neutron- induced charged particles contribute towards the response of CR-39 detectors. Material and Methods: Electrochemical...
متن کاملProtective effect of crocin on electromagnetic field-induced testicular damage and heat shock protein A2 expression in male BALB/c mice
Objective(s): Exposure to electromagnetic fields (EMF) emitted from mobile phones may cause a deleterious effect on human health and may affect the male reproductive system. Crocin, a carotenoid isolated from Crocus Sativus L. (Saffron), is a pharmacologically active component of saffron. So, this study was conducted to investigate the protective effect of crocin on t...
متن کاملNew Calibrations and Time Stability of the Response of the INTERCAST CR-39
We present new calibrations of different production batches (from 1989 to 1999) of the INTERCAST CR-39, using the BNL-AGS 1 A GeV iron beam. The comparison with previous results, obtained with the 158 A GeV lead beam from the CERN-SPS shows that, while each production batch has a different calibration curve (mainly due to minor differences in the production conditions), the aging effect is negl...
متن کامل