A randomised comparative study of Miller laryngoscope blade versus Oxiport® Miller laryngoscope blade for neonatal and infant intubations

نویسندگان

  • Raylene Dias
  • Nandini Dave
  • Rachana Chhabria
  • Harick Shah
  • Madhu Garasia
چکیده

BACKGROUND AND AIMS Neonates and infants are prone to oxygen desaturation during the induction of general anaesthesia. Pharyngeal oxygen insufflation has been shown to delay the onset of desaturation and hypoxaemia during apnoea. We tested the hypothesis that deep laryngeal oxygenation with Oxiport® Miller blade would delay the onset of desaturation compared to laryngoscopy without supplemental oxygen (Miller blade). METHODS One hundred neonates and infants undergoing general anaesthesia with endotracheal intubation for surgery were recruited and randomly assigned to one of the two groups: Miller or Oxiport group (laryngoscopy performed with Miller or Oxiport® blade, respectively). Primary outcome measure was the lowest oxygen saturation (SpO2) attained during intubation. Secondary outcomes were the incidence of severe desaturation (SpO2< 85%), correlation between SpO2and time to intubation in each group. Pearson's correlation coefficient was used to measure the correlation between time to intubation and desaturation in each group. P < 0.05 was considered statistically significant. RESULTS Data from 95 patients were available for the final analysis: Miller group (n = 48) and Oxiport group (n = 47). Mean lowest SpO2was 95.9% ± 5.75% in Miller group and 97.55% ± 2.93% in Oxiport group (P = 0.049). Correlation between time to intubation and SpO2was -0.110; P = 0.459 in Miller group and -0.468; P = 0.001 in Oxiport group. Severe desaturation occurred in 12.5% patients in Miller group and none in Oxiport group. CONCLUSION Apnoeic laryngeal oxygen insufflation with Oxiport® laryngoscope blade decreases the incidence of severe desaturation during neonatal and infant intubations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of cervical spine immobilization technique and laryngoscope blade selection on an unstable cervical spine in a cadaver model of intubation.

STUDY OBJECTIVE Orotracheal intubation (OTI) is commonly used to establish a definitive airway in major trauma victims, with several different cervical spine immobilization techniques and laryngoscope blade types used. This experimental, randomized, crossover trial evaluated the effects of manual in-line stabilization and cervical collar immobilization and 3 different laryngoscope blades on cer...

متن کامل

Design evaluation of commonly used rigid and levering laryngoscope blades.

BACKGROUND The shape of a laryngoscope blade affects the exposition of the larynx. This study evaluates and compares some rigid and levering blade designs based on previous investigative X-ray laryngoscopic studies. METHODS Five rigid laryngoscope blades (Miller #3, Standard Macintosh #3, Classical Macintosh #4 and English-Macintosh #3 and #4) and two levering laryngoscope blades (McCoy in ne...

متن کامل

Effect of C-MAC Video Laryngoscope-aided intubations Using D-Blade on Incidence and Severity of Postoperative Sore Throat

Background Video laryngoscope-aided intubations require less force to align oral, pharyngeal, and laryngeal planes to visualize the glottis opening during intubation. Aim The primary objective of the study was to assess the incidence and severity of postoperative sore throat (POST) in patients who were intubated with C-MAC video laryngoscope using D-blade versus traditional Macintosh laryngos...

متن کامل

RESPIRATION AND THE AIRWAY Comparison of the laryngoscopy views with the size 1 Miller and Macintosh laryngoscope blades lifting the epiglottis or the base of the tongue in infants and children <2 yr of age

Editor’s key points † There are few data comparing the Miller and Macintosh (MAC) laryngoscope blades in children aged ,2 yr. † In this study, similar views at laryngoscopy could be obtained with Miller and MAC size 1 blades. † The views with the Miller blade were similar when placed under the epiglottis or into the vallecula. † Views with the MAC blade were better when placed into the vallecul...

متن کامل

مقایسه لارنگوسکوپ میلر و مکین تاش در خارج سازی جسم خارجی از ناحیه هیپوفارنکس به کمک پنس مگیل

Abstract: Aims and Background: Esophageal foreign body can be harmful. Esophagoscopy is the most common method of foreign body extraction. But in many cases during laryngoscopy the foreign body is visible in hypopharynx region and anesthesiologist can remove it with a Magill forceps. In these cases laryngoscopy should give an appropriate and sufficient view from hypopharynx. The aim of this st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 61  شماره 

صفحات  -

تاریخ انتشار 2017