Multiple radial midpupil lid distances: a simple method for lid contour analysis.
نویسندگان
چکیده
PURPOSE To describe a new computerized method for the analysis of lid contour based on the measurement of multiple radial midpupil lid distances. DESIGN Evaluation of diagnostic technology. PARTICIPANTS AND CONTROLS Monocular palpebral fissure images of 35 patients with Graves' upper eyelid retraction and of 30 normal subjects. METHODS Custom software was used to measure the conventional midpupil upper lid distance (MPLD) and 12 oblique MPLDs on each 15° across the temporal (105°, 120°, 135°, 150°, 165°, and 180°) and nasal (75°, 60°, 45°, 30°, 15°, and 0°) sectors of the lid fissure. MAIN OUTCOME MEASURES Mean, standard deviation, 5th and 95th percentiles of the oblique MPLDs obtained for patients and controls. Temporal/nasal MPLD ratios of the same angles with respect to the midline. RESULTS The MPLDs increased from the vertical midline in both nasal and temporal sectors of the fissure. In the control group the differences between the mean central MPLD (90°) and those up to 30° in the nasal (75° and 60°) and temporal sectors (105° and 120°) were not significant. For greater eccentricities, all temporal and nasal mean MPLDs increased significantly. When the MPLDs of the same angles were compared between groups, the mean values of the Graves' patients differed from control at all angles (F = 4192; P<0.0001). The greatest temporal/nasal asymmetry occurred 60° from the vertical midline. CONCLUSIONS The measurement of radial MPLD is a simple and effective way to characterize lid contour abnormalities. In patients with Graves' upper eyelid retraction, the method demonstrated that the maximum amplitude of the lateral lid flare sign occurred at 60° from the vertical midline.
منابع مشابه
Pre- and postoperative quantitative analysis of contour abnormalities in Graves upper eyelid retraction.
PURPOSE One of the most common problems of the surgical management of Graves upper eyelid retraction is the occurrence of eyelid contour abnormalities. In the present study, the postoperative contour of a large sample of eyelids of patients with Graves orbitopathy was measured. METHODS The postoperative upper eyelid contour of 62 eyes of 43 patients with Graves orbitopathy was subjectively cl...
متن کاملComparison of Single Rhomboid vs Double Rhomboid Silicon Band Frontalis Suspensionin Terms of Upper Lid Contour in Ptosis Surgery
Aim: To compare the effect of single rhomboid and double rhomboid frontalis suspension using 2 mm silicon band on upper lid contour in ptosis surgery. Methods: This randomized control study was conducted at the Department of Ophthalmology, Nishtar Hospital, Multan from March 2011 to March 2014. A total of 40 patients with unilateral ptosis were included in the study. Patients were divided into ...
متن کاملEffect of Insulated Up and Down Lid Motion on the Heat Transfer of a Lid-Driven Cavity with an attached fin
This study investigates the effect of lid motion on the optimal characteristics a thin rectangular fin attached on the hot wall of a square lid-driven cavity with active vertical walls. The optimal fin position is studied for Richardson numbers of 0.1-10. The effect of mounting a rectangular fin with a thermal conductivity of 1 and 1000 on minimization and maximization of heat transfer through ...
متن کاملModified Frontalis Sling Procedure with Lid Crease Formation
PURPOSE To report the results of a modified frontalis sling procedure using Mersilene mesh for correction of upper lid ptosis associated with poor levator muscle function. METHODS This interventional case series included 10 patients (15 eyelids) with congenital ptosis and poor levator function. All subjects underwent the upper lid sling procedure with modifications. Main outcomes were lid cre...
متن کاملCharacterization of unsteady double-diffusive mixed convection flow with soret and dufour effects in a square enclosure with top moving lid
The present study considers the numerical examination of an unsteady thermo-solutal mixed convection when the extra mass and heat diffusions, called as Soret and Dufour effects, were not neglected. The numerical simulations were performed in a lid-driven cavity, where the horizontal walls were kept in constant temperatures and concentrations. The vertical walls were well insulated. A finite vol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmology
دوره 119 3 شماره
صفحات -
تاریخ انتشار 2012