Pre-clinical quantitative imaging and mouse-specific dosimetry for 111In-labelled radiotracers

نویسندگان

  • Ana M. Denis-Bacelar
  • Sarah E. Cronin
  • Chiara Da Pieve
  • Rowena L. Paul
  • Sue A. Eccles
  • Terence J. Spinks
  • Carol Box
  • Adrian Hall
  • Jane K. Sosabowski
  • Gabriela Kramer-Marek
  • Glenn D. Flux
چکیده

BACKGROUND Accurate quantification in molecular imaging is essential to improve the assessment of novel drugs and compare the radiobiological effects of therapeutic agents prior to in-human studies. The aim of this study was to investigate the challenges and feasibility of pre-clinical quantitative imaging and mouse-specific dosimetry of 111In-labelled radiotracers. Attenuation, scatter and partial volume effects were studied using phantom experiments, and an activity calibration curve was obtained for varying sphere sizes. Six SK-OV-3-tumour bearing mice were injected with 111In-labelled HER2-targeting monoclonal antibodies (mAbs) (range 5.58-8.52 MBq). Sequential SPECT imaging up to 197 h post-injection was performed using the Albira SPECT/PET/CT pre-clinical scanner. Mice were culled for quantitative analysis of biodistribution studies. The tumour activity, mass and percentage of injected activity per gram of tissue (%IA/g) were calculated at the final scan time point and compared to the values determined from the biodistribution data. Delivered 111In-labelled mAbs tumour absorbed doses were calculated using mouse-specific convolution dosimetry, and absorbed doses for 90Y-labelled mAbs were extrapolated under the assumptions of equivalent injected activities, biological half-lives and uptake distributions as for 111In. RESULTS For the sphere sizes investigated (volume 0.03-1.17 ml), the calibration factor varied by a factor of 3.7, whilst for the range of tumour masses in the mice (41-232 mg), the calibration factor changed by a factor of 2.5. Comparisons between the mice imaging and the biodistribution results showed a statistically significant correlation for the tumour activity (r = 0.999, P < 0.0001) and the tumour mass calculations (r = 0.977, P = 0.0008), whilst no correlation was found for the %IA/g (r = 0.521, P = 0.29). Median tumour-absorbed doses per injected activity of 52 cGy/MBq (range 36-69 cGy/MBq) and 649 cGy/MBq (range 441-950 cGy/MBq) were delivered by 111In-labelled mAbs and extrapolated for 90Y-labelled mAbs, respectively. CONCLUSIONS This study demonstrates the need for multidisciplinary efforts to standardise imaging and dosimetry protocols in pre-clinical imaging. Accurate image quantification can improve the calculation of the activity, %IA/g and absorbed dose. Diagnostic imaging could be used to estimate the injected activities required for therapeutic studies, potentially reducing the number of animals used.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of radiation dose to anthropomorphic paediatric models from positron-emitting labelled tracers.

PET uses specific molecules labelled with positron-emitting radionuclides to provide valuable biochemical and physiological information. However, the administration of radiotracers to patients exposes them to low-dose ionizing radiation, which is a concern in the paediatric population since children are at a higher cancer risk from radiation exposure than adults. Therefore, radiation dosimety c...

متن کامل

Quantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study

Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...

متن کامل

A comparison of 2D and 3D kidney absorbed dose measures in patients receiving 177Lu-DOTATATE

Objective(s): To investigate and compare quantitative accuracy of kidney absorbed dose measures made from both 2D and 3D imaging in patients receiving 177LuDOTATATE (Lutate) for treatment of neuroendocrine tumours (NETs). Methods: Patients receiving Lutate therapy underwent both whole body planar imaging and SPECT/CT imaging over the kidneys at time points 0.5, 4, 24, and 96-120 hours after inj...

متن کامل

Preparation, formulation and quality control of one step kit 99mTc- EDDA/HYNIC-Tyr3-Octreotide as a peptide radiopharmaceutical for imaging somatostatin receptor positive tumors [Persian]

The high expression of somatostatin receptors in many tumours, have made receptor scintigraphy with 111In-DTPA-Octreotide a widly used procedure in nuclear medicine. Despite its clinical success, some limitation and drawbacks of radiolabelling with 111In remain, especially those concerned with the cost, availability and physical decay properties of this radionuclide. 99mTc-EDDA/HYNIC-Tyr3...

متن کامل

Development of 111In-labeled porphyrins for SPECT imaging

Objectives: The aim of this research was the development of 111In-labeled porphyrins as possible radiopharmaceuticals for the imaging of tumors. Methods: Ligands, 5, 10, 15, 20-tetrakis (3, 5-dihydroxyphenyl) porphyrin) (TDHPP), 5, 10, 15, 20-tetrakis (4-hydroxyphenyl) porphyrin (THPP) and 5, 10, 15, 20-tetrakis (3,4-dimethoxyphenyl) porphyrin) (TDMPP) were labeled with 111InCl3 (produced from ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016