The effect of an interspinous process implant on facet loading during extension.
نویسندگان
چکیده
STUDY DESIGN Facet loading parameters of lumbar cadaver spines were measured during extension before and after placement of an interspinous process implant. OBJECTIVE The study was undertaken to quantify the influence of an interspinous implant on facet loading at the implanted and adjacent levels during extension. SUMMARY OF BACKGROUND DATA Facet loading is increased during extension and decreased during flexion. Previous studies have demonstrated that interspinous process decompression relieves disc pressure at the implanted level and does not alter disc pressure at the adjacent levels. Facet joints are believed to play a key role in back pain, especially in patients with collapsed discs and increased motion segment mobility resulting in increased facet loading. METHODS Seven cadaver spines (L2-L5) were loaded to 15 Nm of extension and 700 N compression with and without an interspinous process implant (X STOP) placed between the L3-L4 spinous processes. Pressure-sensitive film was placed in the facet joints of the implanted and adjacent levels. After loading, the film was digitally analyzed for peak pressure, average pressure, contact area, and force. These values were compared between the intact and implanted specimens at the adjacent and implanted levels using a paired t test (P < 0.05). RESULTS The implant significantly reduced the mean peak pressure, average pressure, contact area, and force at the implanted level. The mean peak pressure, average pressure, contact area, and force at the adjacent levels were not significantly different between the intact and implanted specimens with the exception of contact area at the L2-L3 level. CONCLUSIONS Interspinous process decompression will unlikely cause adjacent level facet pain or accelerated facet joint degeneration. Furthermore, pain induced from pressure originating in the facets and/or posterior anulus of the lumbar spine may be relieved by interspinous pro-cess decompression. Clinical results from patients with a component of lower back pain suggest that this is a valid conclusion.
منابع مشابه
Can a modified interspinous spacer prevent instability in axial rotation and lateral bending? A biomechanical in vitro study resulting in a new idea.
BACKGROUND Interspinous spacers are mainly used to treat lumbar spinal stenosis and facet arthrosis. Biomechanically, they stabilise in extension but do not compensate instability in axial rotation and lateral bending. It would therefore be desirable to have an interspinous spacer available, which provides for more stability also in these two planes. At the same time, the intervertebral disc sh...
متن کاملThe effects of an interspinous implant on the kinematics of the instrumented and adjacent levels in the lumbar spine.
STUDY DESIGN Measurement of the kinematics of the lumbar spine after insertion of an interspinous spacer in vitro. OBJECTIVES To understand the kinematics of the instrumented and adjacent levels due to the insertion of this interspinous implant. SUMMARY OF BACKGROUND DATA An interspinous spacer (X Stop, SFMT, Concord, California) has been developed to treat neurogenic intermittent claudicat...
متن کاملLoad Sharing in L4-L5 Spinal Motion Segment Using an Asymmetrical Finite Element Model
Lumbar spine degeneration diseases require precise prediction of biomechanical parameters. These parameters include stress in ligaments, intradiscal pressure and facet loads. For this purpose, several symmetrical FE models of lumbar spine have been proposed previously with inherent simplifications in design. Such models may not give realistic results for biomechanical analysis because of the as...
متن کاملTreatment of facet cysts associated with neurogenic intermittent claudication with x-stop.
BACKGROUND Facet degeneration often leads to the formation of synovial facet cysts. As facet cysts invade the spinal canal, they become a contributing factor to spinal stenosis. Previous studies have demonstrated successful treatment of neurogenic intermittent claudication (NIC), a major symptom of spinal stenosis, with an interspinous process device. PURPOSE To compare clinical outcomes of p...
متن کاملFusion after interspinous device placement.
Lumbar interspinous devices are intended to unload the facet joints, restore foraminal height, lower intradisk pressure, and provide motion-preserving stabilization. They are an alternative treatment for patients with spinal degeneration and have increased in popularity in recent years. To the authors' knowledge, heterotopic ossification has not been previously reported around an interspinous d...