Comparison of effectiveness and cost of patent ductus arteriosus device occlusion versus surgical ligation of patent ductus arteriosus

نویسندگان

  • Arif Zulqarnain
  • Muhammad Younas
  • Tariq Waqar
  • Ahsan Beg
  • Touseef Asma
  • Mirza Ahmad Raza Baig
چکیده

OBJECTIVES Comparison of effectiveness and cost of transcatheter occlusion of patent ductus arteriosus (PDA) with surgical ligation of PDA. METHODS This retrospective comparative study was conducted in the pediatric cardiology department of Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Data of 250 patients who underwent patent ductus arteriosus (PDA) closure either surgical or trans-catheter closure using SHSMA Occluder having weight >5 kg from April 2012 to October 2015 were included in this study. SPSS version 20 was used for data analysis. Quantitative variables were compared using independent sample t-test. Chi-square test and fishers exact was used for qualitative variables. P-value <0.05 was considered statistically significant. RESULTS There were one hundred and twenty (120) patients who underwent transcatheter occlusion of PDA using SHSMA occluder (PDA Device Group) and one hundred and thirty (130) patients who underwent surgical ligation of PDA (Surgical Group). Incidence of residual shunting was two (1.5%) in surgical group and 0 (0.0%) in PDA Device group for one month follow up period. There were 4 (3.1%) major complications in surgical group. The rate of blood transfusions were high in surgical group (p-value 0.04). Hospital stay time was significantly less in PDA Device group (P-value <0.001). Total procedural cost was 110695+1054 Pakistani rupees in PDA Device group and 92414+3512 in surgical group (p-value <0.001). The cost of PDA device closure was 16.52% higher than the surgical ligation of PDA. There was no operative mortality. CONCLUSION The transcatheter closure of PDA is an effective and less invasive method as compared to the surgical ligation. There is a lower rate of complications and the cost is not much high as compared to surgical PDA ligation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intravenous Paracetamol and Patent Ductus Arteriosus Closure

Background: Standard medical treatments for patent ductus arteriosus (PDA) closure are, including indomethacin/ibuprofen and surgical ligation. Nowadays, a new strategy to close PDA is the use of paracetamol. The present study aimed to describe the use of intravenous (IV) paracetamol for PDA closure in neonates who present a contraindication to ibuprofen or ibuprofen failure with no possibility...

متن کامل

Patent ductus arteriosus in a lamb: A case report

Patent ductus arteriosus (PDA) is a persistent patency of a vessel normally present in the fetus that connects the pulmonary arterial system to the aorta. The ductus arteriosus fails to close at birth when breathing commences and placental blood circulation is removed. Closure of the ductus arteriosus arises in response to decline pulmonary vascular resistance and increased systemic vascular re...

متن کامل

Comparison of Outcomes and Costs of Transcatheter Therapeutic Intervention and Surgical Ligation for the Treatment of Patent Ductus Arteriosus.

Dear Editor, Patent ductus arteriosus (PDA) is a persistence of fetal communication, ductus arteriosus, which connects the aorta and pulmonary artery. One of the most common congenital heart conditions, PDA accounts for approximately 10% of all congenital heart defects.1 Closure of the PDA (other than the silent duct) is recommended to prevent congestive heart failure, infection and pulmonary h...

متن کامل

Does change in serum cholesterol of a population influence coronary heart disease mortality?

[1] Shim D, Fedderly RT, Beekman III RH, Ludomirsky A, Young ML, Schork MA, Lloyd TR. Follow-up of coil occlusion of patent ductus arteriosus. J Am Coll Cardiol 1996; 28. 207-11. [2] Galal O, de Moor M, Fadley F et al. Problems encountered during introduction of Gianturco coils for transcatheter occlusion of the patent arterial duct. Eur Heart J 1997; 18: 625-30. [3] Sommer RJ, Gutierrez A, Lai...

متن کامل

Evaluating the Clinical Course of Patent Ductus Arteriosus after Discharge and Comparing in Therapies Techniques

Background Patent ductus arteriosus is an open channel between the aorta and pulmonary artery. The study aimed to evaluate the clinical course of patent ductus arteriosus after discharge and comparing in therapies technique. Materials and Methods This cross-sectional and inferential- descriptive study was performed in the hospitals of city of Zahedan-Iran in the period of one decade from 2005 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2016