Hydrogel lens monomer constituents modulate protein sorption.

نویسندگان

  • Q Garrett
  • B Laycock
  • R W Garrett
چکیده

PURPOSE To examine the effect of hydrogel lens monomer constituents on protein sorption. METHODS A series of hydroxyethylmethacrylate (HEMA)-based hydrogels with various amounts of methacrylic acid (MAA) or N-vinyl pyrrolidone (NVP) were synthesized. A radiolabel tracer technique was used to measure the amount of protein adsorbed on or penetrating into the hydrogels. Penetration of fluorescence-labeled proteins in the hydrogels was studied by laser scanning confocal microscopy. Single-protein solutions of human serum albumin (HSA) and hen egg lysozyme were studied. RESULTS Inclusion of the comonomers MAA or NVP in hydrogels resulted in an increase in water content and also had a strong impact on protein sorption. An increase in the amount of MAA in the poly(HEMA-co-MAA) hydrogels increased lysozyme adsorption and penetration but reduced HSA adsorption. However, the amount of protein adsorbed for both HSA and lysozyme increased with the amount of NVP in the poly(HEMA-co-NVP) hydrogels. In contrast to the marked effect of MAA on protein sorption, in particular, on lysozyme sorption, NVP had little influence on protein sorption. When a hydrogel contains both MAA and NVP, MAA has the dominant effect on protein sorption-in particular, on lysozyme sorption. Furthermore, a large difference was observed in the amount of lysozyme adsorbed on the hydrogels that had similar water contents but little variation in adsorption of HSA. CONCLUSIONS Negatively charged carboxyl groups of the MAA constituent may influence lysozyme sorption in two ways: by electrostatic attraction and by increasing the possibility for the small lysozyme molecule to penetrate the hydrogels. Interactions of the surface lactam groups of NVP with proteins may be attributable to the attraction of proteins to NVP. Water content is not a primary factor in determining protein adsorption. It appears that the monomer constituents, such as MAA or NVP, control protein adsorption.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A high mechanical strength hydrogel from polyacrylamide/polyacrylamide with interpenetrating network structure by two-steps synthesis method

A simple two-steps polymerization method was used to prepare a polyacrylamide hydrogel with a full interpenetrating network structure based on the sorption and porous properties of polyacrylamide superabsorbent. In conditions of 10 g acrylamide monomer, 0.04 g crosslinker for the first polymerization and the second polymerization, respectively, and the swelling ratio of 9, the hydrogel possesse...

متن کامل

Glucose-responsive hydrogel electrode for biocompatible glucose transistor

In this paper, we propose a highly sensitive and biocompatible glucose sensor using a semiconductor-based field effect transistor (FET) with a functionalized hydrogel. The principle of the FET device contributes to the easy detection of ionic charges with high sensitivity, and the hydrogel coated on the electrode enables the specific detection of glucose with biocompatibility. The copolymerized...

متن کامل

Lysozyme sorption in hydrogel contact lenses.

PURPOSE To examine the processes involved in formation of protein deposits on hydrogel contact lenses. METHODS The adsorption and/or penetration of lysozyme on or into three types of contact lenses, etafilcon A, vifilcon A, and tefilcon, were investigated in vitro using a radiolabel-tracer technique, x-ray photoelectron spectroscopy, and laser scanning confocal microscopy. RESULTS Binding o...

متن کامل

The study of Lysozyme adsorption onto 2-hydroxyethylmethacrylates and Silicon Hydrogel Contact Lenses

In order to increase the water content and the oxygen permeability of hydrogels used in themanufacture of contact lenses, the polar monomer Silicon Hydrogel Contact Lenses (SHCL), and 2-hydroxyethyl methacrylate (HEMA) were copolymerized with the hydrogels. Due to the presence ofpolar monomers in the conventional contact lenses, the major component of the human tear,lysozyme is extensively adso...

متن کامل

Macroporous thermosensitive imprinted hydrogel for recognition of protein by metal coordinate interaction.

A thermosensitive macroporous hydrogel showing selectivity for the lysozyme was developed by an imprinting procedure that is based on metal coordinate interaction. A metal chelate monomer [N-(4-vinyl)-benzyl iminodiacetic acid] forming coordination complex with the template protein in the presence of Cu ions co-polymerized with N-isopropylacrylamide and acrylamide, using N,N-methylenebisacrylam...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 41 7  شماره 

صفحات  -

تاریخ انتشار 2000