A new method for estimating hand internal loads from external force measurements.

نویسندگان

  • C B Irwin
  • R G Radwin
چکیده

This study examines using force vectors measured using a directional strain gauge grip dynamometer for estimating finger flexor tendon tension. Fifty-three right-handed participants (25 males and 28 females) grasped varying-sized instrumented cylinders (2.54, 3.81, 5.08, 6.35 and 7.62 cm diameter) using a maximal voluntary power grip. The grip force vector magnitude and direction, referenced to the third metacarpal, was resolved by taking two orthogonal grip force measurements. A simple biomechanical model incorporating the flexor tendons was used to estimate long finger tendon tension during power grip. The flexor digitorum superficialis and the flexor digitorum profundus were assumed to create a moment about the metacarpal phalange (MCP) joint that equals and counteracts a moment around the MCP joint measured externally by the dynamometer. The model revealed that tendon tension increased by 130% from the smallest size handle to the largest, even though grip force magnitude decreased 36% for the same handles. The study demonstrates that grip force vectors may be useful for estimating internal hand forces.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Nonlinear Voltage Stability Index based on Vector Analysis Method and Measurements of Active and Reactive Powers of Power System

This paper proposes a new voltage stability assessment method based on vector analysis method. This index extraction process relies on measurements of active and reactive powers from connected buses to the generator buses. Therefore, a limit for beginning of voltage collapse is determined based on the maximum power transfer theory. On the other hand, when the system requires load shedding, a ne...

متن کامل

The role of internal models in motion planning and control: evidence from grip force adjustments during movements of hand-held loads.

We investigated the issue of whether or not the CNS makes use of an internal model of the motor apparatus in planning and controlling arm movements. In particular, we tested the ability of subjects to predict different hand-held loads by examining grip force adjustments used to stabilize the load in the hand during arm movements. Subjects grasped a manipulandum using a precision grip with the t...

متن کامل

Effect of Gold Nanoparticles on Prostate Dose Distribution under Ir-192 Internal and 18 MV External Radiotherapy Procedures Using Gel Dosimetry and Monte Carlo Method

Background: Gel polymers are considered as new dosimeters for determining radiotherapy dose distribution in three dimensions.Objective: The ability of a new formulation of MAGIC-f polymer gel was assessed by experimental measurement and Monte Carlo (MC) method for studying the effect of gold nanoparticles (GNPs) in prostate dose distributions under the internal Ir-192 and external 18MV radiothe...

متن کامل

بررسی تکرارپذیری نیروی عکس العمل زمین حین استفاده از ابزار اعمال اغتشاش اندام تحتانی در حرکت ایستادن روی یک پا

Introduction: The aim of the current study was to measure ground reaction force and center of pressure (COP) during lower extremity perturbation in single leg standing whit knee flexion and extension in healthy subjects, in addition to revealing reliability of the device used for the related perturbation for using another studies, reliability is one of the characteristic of measuring instrumen...

متن کامل

Integration of Vision and Force Sensors for Grasping - Multisensor Fusion and Integration for Intelligent Systems, 1996., IEEE/SICE/RSJ International Con

This paper describes a set of methods that can be used to integrate real-time external vision sensing with internal force and position sensing to estimate contact forces by the fingers of a hand. Estimating these forces and contacts is essential to performing dextrous manipulation tasks. Most robotic hands are either sensorless or lack the ability to accurately and robustly report position and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ergonomics

دوره 51 2  شماره 

صفحات  -

تاریخ انتشار 2008