Hemocue urine albumin point-of-care test shows strong agreement with the results obtained with a large nephelometer.

نویسندگان

  • Gösta Florvall
  • Samar Basu
  • Johanna Helmersson
  • Anders Larsson
چکیده

There is an increasing incidence of diabetic nephropathy, predominantly in patients with type 2 diabetes (1– 3). Persistent microalbuminuria is a sign of ongoing glomerular injury and a strong predictor of clinical nephropathy, and screening for microalbuminuria, the earliest manifestation of diabetic nephropathy, is recommended for all diabetic patients (4). Point-of-care testing (POCT) offers rapid test results, which facilitate the use of the results to motivate the patient to lifestyle changes and increased compliance (5–7). To achieve good compliance, it is essential that the patient and physician work together and that the patient get regular feedback on the treatment results. The feedback is considered to be more effective if the test results are available during the consultation. This has led to the development of POCT instruments for measuring urine albumin excretion. The aim of the present study was to evaluate urine albumin analyzed by the HemoCue POCT instrument, which can provide rapid test results, in relation to urine albumin analyzed by a central laboratory instrument (ProSpec) and the albumin-to-creatinine ratio (ACR) in a group of elderly men.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microalbuminuria, blood pressure and cardiovascular risk factors in elderly males

Objective To correlate blood pressure and inflammatory markers with urine albumin analysed with a point-of-care testing (POCT) instrument, nephelometric determination of albumin and creatinine related urine albumin in elderly males. Methods and Results The study population consisted of 103 diabetic and 603 nondiabetic males (age 77 years) in a cross-sectional study in central Sweden. We analyze...

متن کامل

Microalbuminuria Measured by three Different Methods, Blood Pressure and Cardiovascular Risk Factors in Elderly Swedish Males

Microalbuminuria is associated with hypertension and is a strong risk factor for subsequent chronic disease, both renal and coronary heart disease (CHD), Presently there are several methods available for measurement of microalbuminuria. The aim of this study was to evaluate if the three different methods gave similar information or if one of the assays were superior to the others. Blood pressur...

متن کامل

Identifying high and low serum-ascites albumin gradient in ascitic fluid by the point of care dipstick test

Objective: To evaluate the capability of ascitic fluid dipstick results for pH, glucose, and protein in order to predict a low serum-ascites albumin gradient (SAAG) at the bedside of the patient in the emergency department (ED). Methods: This prospective cross-sectional study was conducted during one year in the ED of Afzalipour hospital in Kerman, Iran. ...

متن کامل

ارزیابی روش‌های الکتروایمونواسی و 100Clinitek- برای تشخیص میکروآلبومینوری

Evaluation of Electroimmunoassay and Clinitek-100 for Detection of Microalbuminuria B.A. Jalali Khanabadi PhD , H. Mozaffari Khosravi PhD Received: 12/10/05 Sent for Revision: 04/03/06 Received Revised Manuscript: 20/01/07 Accepted: 25/01/07 Background and Objective: Detection of microalbuminuria is an important laboratory test for evaluation of diabetic complications. A reliable me...

متن کامل

Comparison of the accuracy of noninvasive hemoglobin monitoring by spectrophotometry (SpHb) and HemoCue® with automated laboratory hemoglobin measurement.

BACKGROUND The reference method for hemoglobin concentration measurement remains automated analysis in the laboratory. Although point-of-care devices such as the HemoCue® 201+ (HemoCue, Ängelholm, Sweden) provide immediate hemoglobin values, a noninvasive, spectrophotometry-based technology (Radical-7®; Masimo Corp., Irvine, CA) that provides continuous online hemoglobin (SpHb) measurements has...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diabetes care

دوره 29 2  شماره 

صفحات  -

تاریخ انتشار 2006