Non-invasive imaging prior to cryoballoon ablation of atrial fibrillation: what can we learn?

نویسندگان

  • Alexander Fürnkranz
  • Feifan Ouyang
چکیده

Cryoballoon pulmonary vein isolation (CB-PVI) is attractive for many electrophysiologists because the device allows in principle to isolate the pulmonary veins (PVs) with a single application and a short learning curve. In order to achieve an effective lesion, the cryoballoon must be positioned with good circumferential tissue contact at the PV ostium, usually ascertained by the absence of contrast media run-off from the balloon tip into the left atrium during PV angiography. 3 This means that the operator has to face a wide variety of left atrial and PV anatomies with a pre-shaped device that cannot be adapted to a patient’s individual anatomy. Device selection is further limited in that the use of the smaller of the two available cryoballoon dimensions (23 and 28 mm) may impose an increased risk of right phrenic nerve palsy (PNP). To overcome this difficulty, different catheter manoeuvres have to be performed to achieve successful balloon positioning. Although the endpoint of complete PVI may be accomplished with these techniques in the great majority of patients, the individual anatomy impacts on success, ease, and safety of the procedure. Sorgente et al. present a retrospective analysis in 52 patients who underwent CB-PVI using the 28 mm cryoballoon (and a radiofrequency catheter if PVI was not achievable with the balloon). A semi-quantitative evaluation of PV occlusion by the cryoballoon was correlated with two anatomical parameters acquired by preprocedural multislice computed tomography imaging (MSCT): the ratio between the maximal and minimal PV ostial diameter (a measure of PV ‘ovality’) and the angle between the PV longitudinal and the frontal body axis. An inverse correlation between the PV ovality index and balloon occlusion grade was found for lateral PVs (which exhibited a higher ovality index when compared with septal PVs). In addition, the more the PV long axis deviated inferiorly in the frontal plane, the lower was the occlusion grade. This may be explained by the fact that a high contact force—by simultaneously pushing the sheath and balloon—can be achieved in the superior, but not in the inferior, direction. This is reflected by a dominance of inferiorly located conduction gaps in patients presenting with recurrent atrial fibrillation following CB-PVI. Of note, despite these anatomical differences, PVI was achieved in 94% of the PVs at first testing after ablation. A focal radiofrequency catheter was used in 6% of PVs to complete isolation. Thus, had patients been selected prospectively on the basis of the analysed parameters, pre-procedural MSCT had added little to the high acute success rate of the procedure. However, although not investigated in the present study, imperfect occlusion may also affect chronic PVI, possibly due to inhomogeneous lesion formation. Thus, several questions remain to be addressed concerning noninvasive imaging prior to CB-PVI. Perhaps the most interesting subject of future studies is the possible impact of anatomy on chronic success of CB-PVI. In other words, may pre-procedural imaging identify a patient population with a greater long-term efficacy based on left atrium and PV anatomy particularly suitable to the cryoballoon? By showing the association between PV ostial shape/orientation and PV occlusion, Sorgente et al. provided the first analysis of candidate anatomical parameters to be used in such a study. Another issue is the wide variation in the average procedure duration reported in clinical studies of CB-PVI, up to 370 min in the North American Arctic Front STOP-AF (Sustained Treatment Of Paroxysmal Atrial Fibrillation) trial, recently presented at the Annual Scientific Session in Atlanta in March 2010 and at the Heart Rhythm Society meeting in Denver in May 2010. Procedure duration is subject to the learning curve, raising the question whether pre-procedural imaging may (at least initially) help in patient selection in less experienced centres. Finally, can pre-procedural imaging improve the safety of CB-PVI? The most common complication of CB-PVI is right PNP. Since the incidence of PNP is related to the cryoballoon position relative to the PV ostium, PNP may occur even with

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute esophageal tissue reaction after Cryoballoon ablation in patients with paroxysmal atrial fibrillation - a LGE-MRI Study

Background Esophageal wall thermal injury after Cryoballoon ablation is a potentially serious complication. Late-Gadolinium Enhancement MRI (LGE-MRI) allows an accurate and non-invasive detection of acute tissue reaction. We thought to compare the relationsship of acute esophageal tissue reaction detected using LGE-MRI acute after pulmonary vein isolation (PVI) with the Arctic Front (AF) and th...

متن کامل

Nonfluoroscopic Ablation of Atrial Fibrillation Using Cryoballoon.

BACKGROUND The conventional method of cryoballoon ablation of atrial fibrillation involves the use of fluoroscopy for visual guidance. The use of fluoroscopy is accompanied by significant radiation risks to the patient and the medical staff. Herein, we report our experience in performing successful nonfluoroscopic pulmonary vein isolation using cryoballoon ablation in 5 consecutive patients wit...

متن کامل

Eccentric scar formation around a pulmonary vein after cryo-balloon ablation in a patient with atrial fibrillation: A case report

The impact of a cryoballoon ablation is reported to be similar to that of a radiofrequency (RF) ablation in patients with atrial fibrillation. Delayed enhancement magnetic resonance imaging (DE-MRI) could visualize the scar region induced by the cryoballoon ablation as well as RF ablation. Cryoballoon ablation could induce extensive scar lesions around the PVs. However, the distribution of the ...

متن کامل

Recurrent and late-onset coronary spasms after cryoballoon ablation procedure in a patient with atrial fibrillation

The feasibility of cryoballoon ablation for treating paroxysmal atrial fibrillation (AF) has been reported. On the other hand, several complications specific to ablation using a cryoballoon may be expected. The prior reports of coronary spasms during procedures describe some mechanisms of coronary spasms; however, those mechanisms remain unknown. We describe a case of recurrent and late-onset c...

متن کامل

Cryoballoon Ablation for Atrial Fibrillation

Focal point-by-point radiofrequency catheter ablation has shown considerable success in the treatment of paroxysmal atrial fibrillation. However, it is not without limitations. Recent clinical and preclinical studies have demonstrated that cryothermal ablation using a balloon catheter (Artic Front©, Medtronic CryoCath LP) provides an effective alternative strategy to treating atrial fibrillatio...

متن کامل

Comparing Safety and Efficacy of Irrigated Radiofrequency Catheter Ablation Versus Combined Cryoballoon and Catheter Ablation for Persistent Atrial Fibrillation.

Background: Catheter and cryoballoon ablation are established treatments for atrial fibrillation. Frequently, substrate modification of the left atrium is performed in patients with persistent AF or evidence of left atrial adverse remodeling. We compared one year outcomes of AF ablation with substrate modification utilizing radiofrequency catheter ablation (RFA) compared to a combination of cry...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 13 2  شماره 

صفحات  -

تاریخ انتشار 2011