Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty

نویسندگان

  • Brad Ellison
  • Nicholas A Cheney
  • Keith R Berend
  • Adolph V Lombardi
  • Thomas H Mallory
چکیده

BACKGROUND As longevity of cementless femoral components enters the third decade, concerns arise with long-term effects of fixation mode on femoral bone morphology. We examined the long-term consequences on femoral remodeling following total hip arthroplasty with a porous plasma-sprayed tapered titanium stem. METHODS Clinical data and radiographs were reviewed from a single center for 97 randomly selected cases implanted with the Mallory-Head Porous femoral component during primary total hip arthroplasty. Measurements were taken from preoperative and long-term follow-up radiographs averaging 14 years postoperative. Average changes in the proximal, middle and diaphyseal zones were determined. RESULTS On anteroposterior radiographs, the proximal cortical thickness was unchanged medially and the lateral zone increased 1.3%. Middle cortical thickness increased 4.3% medially and 1.2% laterally. Distal cortical thickness increased 9.6% medially and 1.9% laterally. Using the anteroposterior radiographs, canal fill at 100 mm did not correlate with bony changes at any level (Spearman's rank correlation coefficient of -0.18, 0.05, and 0.00; p value = 0.09, 0.67, 0.97). On lateral radiographs, the proximal cortical thickness increased 1.5% medially and 0.98% laterally. Middle cortical thickness increased 2.4% medially and 1.3% laterally. Distal cortical thickness increased 3.5% medially and 2.1% laterally. From lateral radiographs, canal fill at 100 mm correlated with bony hypertrophy at the proximal, mid-level, and distal femur (Spearman's rank correlation coefficient of 0.85, 0.33, and 0.28, respectively; p value = 0.001, 0.016, and 0.01, respectively). CONCLUSION Stress shielding is minimized with the Mallory-Head titanium tapered femoral stem with circumferential proximal plasma-sprayed coating in well-fixed and well-functioning total hip arthroplasty. Additionally, the majority of femora demonstrated increased cortical thickness in all zones around the stem prosthesis. LEVEL OF EVIDENCE Therapeutic Level III.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bone density study of the proximal femur after hip arthroplasty with porous-coated implants

Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...

متن کامل

Effects of stemmed and nonstemmed hip replacement on stress distribution of proximal femur and implant

BACKGROUND Despite improvements in shape, material, and coating for hip stem, both stress shielding and aseptic loosening have been the major drawbacks of stemmed hip arthroplasty. Some nonstemmed systems were developed to avoid rasping off the intramedullary canal and evacuating the bone marrow due to stem insertion. METHODS In this study, the finite-element models of one intact, one stemmed...

متن کامل

Total hip arthroplasty using proximal porous coating stem with distal sleeve: mid-term outcome.

PURPOSE To report mid-term results of total hip arthroplasty (THA) using the Opti-Fix Plus Hip System (Opti-Fix Hip), and to assess the correlations between peri-implant bone changes and the distal medullary occupancy rate. METHODS 11 men (13 hips) and 53 women (58 hips) aged 24 to 87 (mean, 61) years underwent THA using the Opti-Fix Hip, with a modular stem and a distal sleeve, and were foll...

متن کامل

Short femoral stem and porous titanium: winning combination?

A lot of different implants are available in hip replacement arthroplasty (THA), stems differ mainly by type of fixation, material, length, diameter, shape, surface coating, modularity, etc. The main quality of a non-cemented stem is to pursuit primary and secondary stability, to preserve bone stock, to be adaptable and modular. The literature shows that the most popular non cemented stems used...

متن کامل

Fully porous 3D printed titanium femoral stem to reduce stress-shielding following total hip arthroplasty.

Current hip replacement femoral implants are made of fully solid materials which all have stiffness considerably higher than that of bone. This mechanical mismatch can cause significant bone resorption secondary to stress shielding, which can lead to serious complications such as peri-prosthetic fracture during or after revision surgery. In this work, a high strength fully porous material with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2009