Functional changes in coronary microcirculation after valve replacement in patients with aortic stenosis.

نویسندگان

  • Kim Rajappan
  • Ornella E Rimoldi
  • Paolo G Camici
  • Nicholas G Bellenger
  • Dudley J Pennell
  • Desmond J Sheridan
چکیده

BACKGROUND Increased extravascular compression and reduced diastolic perfusion time (DPT), rather than vascular remodeling, influence coronary microcirculatory dysfunction in aortic stenosis (AS). However, alterations after aortic valve replacement (AVR) remain unclear. The aim of the present study was to quantify changes in transmural perfusion and coronary vasodilator reserve (CVR), a measure of microcirculatory function, after AVR and determine the relative contribution of left ventricular mass (LVM) regression, change in aortic valve area (AVA), and DPT. METHODS AND RESULTS Twenty-two patients with AS were studied before and 1 year after AVR using echocardiography to measure AVA, cardiovascular magnetic resonance to assess LVM, and positron emission tomography to quantify resting and hyperemic myocardial blood flow (MBF) and CVR. Regression of LVM occurred in all patients (from 129+/-30 to 94+/-24 g/m2; P<0.0001), and there was a significant reduction in resting MBF and increase in CVR corrected for rate-pressure product after AVR, although these changes displayed marked heterogeneity. Regression of LVM was linearly related to change in resting total LV blood flow but not CVR. Increase in hyperemic MBF and CVR transmurally was directly related to the increase in AVA after AVR. A significant relationship existed between the change in hyperemic DPT (1.0+/-4.7 s/min [range, 6.8 to 9.6]) and change in transmural CVR (y=0.08x+0.18; r=0.44; P=0.04). CONCLUSIONS Changes in coronary microcirculatory function in patients with AS after AVR are not directly dependent on regression of LVM. Reduced extravascular compression and increased DPT are proposed as the main mechanisms for improvement in MBF and CVR after AVR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Functional Assessment of Coronary Artery Disease in Patients Undergoing Transcatheter Aortic Valve Implantation: Influence of Pressure Overload on the Evaluation of Lesions Severity.

BACKGROUND Aortic valve stenosis may influence fractional flow reserve (FFR) of concomitant coronary artery disease by causing hypertrophy and reducing the vasodilatory reserve of the coronary circulation. We sought to investigate whether FFR values might change after valve replacement. METHODS AND RESULTS The functional relevance of 133 coronary lesions was assessed by FFR in 54 patients wit...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

عوامل خطر تنگی هموگرافت پولمونر پس ازعمل جراحی Ross

Background: The Ross procedure has been known as a good method for aortic valve replacement. Pulmonary allograft postoperative stenosis subsequent to the Ross procedure has been noted as an important disadvantage of this technique, although risk factors related to this complication are not clearly recognized. In this study we evaluate the risk factors of pulmonary allograft stenosis after Ross ...

متن کامل

Aortic valve replacement for stenosis with or without coronary artery bypass grafting after 2 previous isolated coronary artery bypass grafting operations.

Aortic valve replacement following an earlier coronary artery bypass grafting (CABG) procedure is fairly common. When this situation occurs, the type of valve dysfunction is usually stenosis (with or without regurgitation), and whether it was missed at the time of the earlier CABG or developed subsequently is usually unclear. We attempted to determine the survival in patients who had had aortic...

متن کامل

The non-invasive documentation of coronary microcirculation impairment: role of transthoracic echocardiography

Transthoracic Doppler echocardiographic-derived coronary flow reserve is an useful hemodynamic index to assess dysfunction of coronary microcirculation. Isolated coronary microvascular abnormalities are overt by reduced coronary flow reserve despite normal epicardial coronary arteries. These abnormalities may occur in several diseases (arterial hypertension, diabetes mellitus, hypercholesterole...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 107 25  شماره 

صفحات  -

تاریخ انتشار 2003