PURPOSE To determine correlation between metal hypersensitivity and long-term foot and ankle function and pain after internal fixation using stainless steel implants. METHODS 60 men and 46 women (mean age, 47 years) who underwent internal fixation for ankle fractures completed a questionnaire 13 to 38 (mean, 26) months after surgery to assess their existing medical condition, history of metal hypersensitivity, problems and outcome of the implant (revision or removal), and the American Academy of Orthopaedic Surgeons (AAOS) foot and ankle score. A subset of 12 men and 15 women then underwent patch testing for metal hypersensitivity to molybdenum, chromium, iron, manganese, and nickel. Patients with positive and negative reactions were compared. RESULTS 21 of the 106 patients underwent removal of the metal implants. The AAOS score was not associated with any of the variables, except for a history of metal hypersensitivity from dental implants and irritation around the surgical scar. Multiple linear regression analysis showed that only irritation around the surgical scar remained associated with poorer AAOS scores. Five of the 27 tested patients had a positive reaction. The mean AAOS scores did not differ significantly between patients with positive and negative reactions (34 vs. 31, p=0.73). Gender was not associated with the test results (p=0.63). None of the 5 patients with a positive reaction underwent revision surgery or reported any history of asthma or metal hypersensitivity. Of the 27 patients, one of the 8 who reported itching, irritation, redness or rash around the surgical scar had a positive reaction, compared to 4 of 19 patients who reported no such symptoms (p=1). Two of the 27 patients reported development of eczema after fixation, one of whom had a positive reaction. Only one of the 27 patients reported a history of metal hypersensitivity to jewellery, but had a negative reaction.. CONCLUSION Neither a history of metal hypersensitivity nor positive patch testing correlated with poor outcomes after internal fixation for ankle fractures using stainless steel implants.
منابع مشابه
The Timeliness of Ankle Fracture Management from Presentation to Discharge; Our Experience from a District Eeneral Hospital
Introduction: Unstable ankle fractures are a common presentation and operative intervention has proven to improve patient outcomes. Each stage of patient management can have an impact on patient length of stay and clinical outcome. The aim of the present study is to assess how we manage the patient at each stage from their presentation right through to discharge, and if/how variation in practic...
متن کاملThe Outcomes of Pilon Fracture Treatment: Primary Open Reduction and Internal Fixation Versus Twostage Approach
Background: Pilon fracture is one of the challenging injuries in orthopedic surgery. Associated soft tissue injury is animportant factor in choosing treatment options. Two major methods of treatment are considered as one-stage openreduction internal fixation (ORIF) and two-stage treatment (primary external fixation and secondary ORIF). The latter ismost accepted in literature. In the current st...
متن کاملAbsorbable implants versus metal implants for the treatment of ankle fractures: A meta-analysis
This meta-analysis was performed to evaluate the efficiency and the safety of absorbable implants. Five major electronic databases (PubMed, Embase, Cochrane Library, SinoMed and Wanfang Data) were systematically searched for randomized controlled trials (RCTs) from their establishment to November 2012. Studies on absorbable implants and metal implants for ankle fractures were selected. The meta...
متن کاملLong-term Results After Ankle Syndesmosis Injuries.
Syndesmotic disruption occurs in more than 10% of ankle fractures. Operative treatment with syndesmosis screw fixation has been successfully performed for decades and is considered the gold standard of treatment. Few studies have reported the long-term outcomes of syndesmosis injuries. This study investigated long-term patient-reported, radiographic, and functional outcomes of syndesmosis injur...
متن کاملOutcomes of operative treatment of unstable ankle fractures: a comparison of metallic and biodegradable implants.
BACKGROUND Biodegradable implants for internal fixation of ankle fractures may overcome some disadvantages of metallic implants, such as imaging interference and the potential need for additional surgery to remove the implants. The purpose of this study was to evaluate the outcomes after fixation of ankle fractures with biodegradable implants compared with metallic implants. METHODS In this p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic surgery
دوره 19 3 شماره
صفحات -
تاریخ انتشار 2011