Motion Artifact Reduction for Wearable Photoplethysmogram Sensors Using Micro Accelerometers and Laguerre Series Adaptive Filters by Levi
نویسندگان
چکیده
The photoplethysmogram (PPG) is an extremely useful wearable sensing medical diagnostic tool. However, the PPG signal becomes highly corrupted when the wearer is in motion, rendering the measured signal useless. This thesis develops an adaptive motion artifact reduction scheme to recover the underlying physiologic information from the corrupted signal using a collocated accelerometer as a motion reference and adaptively estimating the motion-to-artifact system dynamics. It has previously been shown that this artifact reduction scheme can be utilized, but many tunable parameters were required to model the system dynamics and performance was poor. This work quantifies algorithm performance based on confidence in the estimated system dynamics, which shows low confidence using the previous parameterization when the wearer is jogging. To improve confidence, the form of the system dynamics is established and a Laguerre series is implimented to compactly represent the system dynamics using just a few parameters that can be confidently estimated. Using the new model, heart rate and amplitude can be estimated from typical jogger data with variance similar to separate PPG sensors located on contralateral motionless hands. The standard artifact reduction scheme does not work when the physiologic signal is correlated with wearer motion. Since the signals may become correlated, this work develops a method of recovering the physiological signal even when it is correlated with wearer motion by adapting blind source seperation techniques. However, the success of this new method is limited. Thesis Supervisor: H. Harry Asada Title: Ford Professor of Mechanical Engineering
منابع مشابه
Active motion artifact cancellation for wearable health monitoring sensors using collocated MEMS accelerometers
This paper presents an active noise cancellation technique for recovering wearable biosensor signals corrupted by bodily motion. A finger mounted photoplethysmograph (PPG) ring sensor with a collocated MEMS accelerometer is considered. The system by which finger acceleration disturbs PPG output is identified and a means of modeling this relationship is prescribed using either FIR or Laguerre mo...
متن کاملCharacterization of Quadratic Nonlinearity between Motion Artifact and Acceleration Data and its Application to Heartbeat Rate Estimation
Accelerometers are applied to various applications to collect information about movements of other sensors deployed at diverse fields ranging from underwater area to human body. In this study, we try to characterize the nonlinear relationship between motion artifact and acceleration data. The cross bicoherence test and the Volterra filter are used as the approaches to detection and modeling. We...
متن کاملBlockwise PPG Enhancement Based on Time-Variant Zero-Phase Harmonic Notch Filtering
So far, many approaches have been developed for motion artifact (MA) reduction from photoplethysmogram (PPG). Specifically, single-input MA reduction methods are useful to apply wearable and mobile healthcare systems because of their low hardware costs and simplicity. However, most of them are insufficiently developed to be used in real-world situations, and they suffer from a phase distortion ...
متن کاملA Novel Time-Varying Spectral Filtering Algorithm for Reconstruction of Motion Artifact Corrupted Heart Rate Signals During Intense Physical Activities Using a Wearable Photoplethysmogram Sensor
Accurate estimation of heart rates from photoplethysmogram (PPG) signals during intense physical activity is a very challenging problem. This is because strenuous and high intensity exercise can result in severe motion artifacts in PPG signals, making accurate heart rate (HR) estimation difficult. In this study we investigated a novel technique to accurately reconstruct motion-corrupted PPG sig...
متن کاملMachine Learning Methods for Classifying Human Physical Activity from On-Body Accelerometers
The use of on-body wearable sensors is widespread in several academic and industrial domains. Of great interest are their applications in ambulatory monitoring and pervasive computing systems; here, some quantitative analysis of human motion and its automatic classification are the main computational tasks to be pursued. In this paper, we discuss how human physical activity can be classified us...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -